=== Monday 14-05-2012 ===
||{{attachment:NikaRun4/miroir_cryo.jpg| The cryostat with its new optics |width=400}}||{{attachment:NikaRun4/alain_miroir_cryo.jpg| the new optics |width=400}}||

=== Saturday 19-05-2012 ===
Je suis a 490 MHz sur la click FPGA soit un bin de 1.869 MHz
je mets 50kHz de deviation modulation sur les 2 bandes
matrice A : 1mm : 2.288149 GHz dac 3db HF 0 db sortie 10db - 1 ampli
matrice B : 2mm : 1.3013 GHz dac 3db HF 20 db sortie directe - 1 ampli

12h51m11_0001_T scan table xy pas 5mm et 20% (50x50)

13h02m45_0002_B un balayage complet des 2 bandes la 1 mm a beaucoup bouge : je recherche les résonances sur les 2 matrices
13h29m01_B Je relance un balayage
13h31m01_0004_T puis une carte scan table xy pas 5mm et 20% (50x50)
13h48m41_B balayage complet la 1mm est montee en frequence de 110 KHz : je recentre la 1mm et ne touche pas a la 2mm
                   petit balayage sur les 2 matrices pour recentrer le bins
13h58m01_0005_T Nouvelle carte avec un pas plus faible (3mm)
   mesures de bruit


{{attachment:NikaRun4/A_2012_05_19_13h58m01_0005_T_2mm_FP_pos.png|2mm matrix |width=400}}
{{attachment:NikaRun4/B_2012_05_19_13h58m01_0005_T_1mm_FP_pos.png|1mm matrix |width=400}}

14h22m30 balayage complet pour regarder les derives: la 1mm est montee de 140 kHz (on est a 181 mK en train de refroidir lineairement 5mK par heure
14h30m57_0006_T encore une carte pas de 5mm apres un reglage pour voir la stabilite de la photometrie
   Il y a des sauts dus à des erreurs sur la roach A (pas d'erreur sur la roachB) : je fais kill dhclient3 (3304.3)
14h40m20_0007_T Un petit balayage et je refaits une carte : a priori, plus d'erreur et plus de sauts

{{attachment:NikaRun4/A_2012_05_19_14h40m20_0007_T_2mm_FP_pos.png|2mm matrix |width=400}}
{{attachment:NikaRun4/B_2012_05_19_14h40m20_0007_T_1mm_FP_pos.png|1mm matrix |width=400}}


14h47m50_T 14h50 : corps noir a 12.32 ohm : je chauffe a 20V 1.3A puis 30V 2A
                       14h56 : corps noir a 13.09 ohm puis ca refroidis a nouveau
                       14h58 : j'enleve le bras et la bille puis je passe 2 fois une feuille de polystyrene
                       mesure de bruit
15h10 : je baisse la puissance de 5db sur la matrice A : dac 3db HF 5 db sortie 5db - 1 ampli
                       la frequence monte encore de 250 KHz : je recentre les resonnances qui sont plus belles
15h18m35_B Un balayage complet matrice A
15h20m08_B un petit balayage pour verifier et recentrer
15h22m50 2 passages d'une feuille de polystyrene puis mesure de bruit