Differences between revisions 13 and 14
Revision 13 as of 2009-01-14 13:43:07
Size: 732
Editor: JuanPenalver
Comment:
Revision 14 as of 2009-01-14 13:45:43
Size: 779
Editor: JuanPenalver
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
 * 2009-01-13, updated by JP, used 35 pointing scans with the B100 receiver. Only the pointing offset parameters P2 and P7 have been modified. The coverage and scatter of the pointing session is available in attachment:PointModel090113.pdf  * 2009-01-13, updated by JP, used 35 pointing scans with the B100 receiver. Only the pointing offset parameters P2 and P7 have been modified. The rms previous and after the fit was 1.9". The coverage and scatter of the pointing session is available in attachment:PointModel090113.pdf.

Heterodyne Pointing Model:

  • 2009-01-13, updated by JP, used 35 pointing scans with the B100 receiver. Only the pointing offset parameters P2 and P7 have been modified. The rms previous and after the fit was 1.9". The coverage and scatter of the pointing session is available in attachment:PointModel090113.pdf.

  • 2009-01-07, update by JP, 16 points, previous rms 9.5" and new rms = 3.4". attachment:point_model090108.pdf. This fit is confirmed by a fit by CK to 89 of in total 231 high-quality observers pointings which were conducted since beginning of this year: attachment:mrt-b100-2-080108.png
  • 2008-06-25, 29 points, previous rms = 2.58", new rms = 1.97". The coverage and scatter of the pointing session were: attachment:coverage.jpg attachment:scatter.jpg

PointingModelFits (last edited 2013-10-05 13:16:25 by mrt-lx7)