Differences between revisions 6 and 7
Revision 6 as of 2020-11-11 07:47:27
Size: 2882
Comment:
Revision 7 as of 2020-11-11 07:53:33
Size: 2901
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
Line 6: Line 5:

The overall goal is to complete the commissioning of the polarization capabilities of the NIKA2 camera, and make the first steps towards Science Verification.
Following the data and their analysis from December 2018 and Feb 2020, the main priorities are:
The overall goal is to complete the commissioning of the polarization capabilities of the NIKA2 camera, and make the first steps towards Science Verification. Following the data and their analysis from December 2018 and Feb 2020, the main priorities are:
Line 20: Line 17:
- Get maps of polarization "leakages" using planets (Uranus) every night to evaluate the precision of correction in « real-conditions »   - Get maps of polarization "leakages" using planets (Uranus) every night to evaluate the precision of correction in « real-conditions »
Line 24: Line 20:
 * '''Visibilities of science verif sources:'''
Line 25: Line 22:
   *'''Visibilities of science verif sources:'''
{{attachment:nika2sv-sources-Nov2020.png||height=500}}
{{attachment:nika2sv-sources-Nov2020.png||height="500"}}
Line 29: Line 24:
   *'''Visibilities of quasars:'''
{{attachment:nika2sv-qso-Nov2020.png||height=500}}
 * '''Visibilities of quasars:'''
Line 33: Line 26:
{{attachment:nika2sv-qso-Nov2020.png||height="500"}}
Line 35: Line 29:
__PaKo:__
Line 36: Line 31:
PaKo:
You open a terminal, and you ssh to mrt-lx1:
>
ssh -XY t22@mrt-lx1
Open PaKo
>goNIKAnew
>set dosubmit yes
  
PIIC
NIKA2 data processing:
For this, you need to connect to mrt-lx3:
>ssh -XY nikas-20@mrt-lx3 
ssh -XY t22@mrt-lx1

goNIKAnew

set dosubmit yes

__PIIC NIKA2 data processing: __

C
onnect to mrt-lx3:

>ssh -XY nikas-20@mrt-lx3
Line 48: Line 44:
>piic @monitorX # replace X with 1, 3, 2pf or 2m. 2pf is the fast queue to get the pointing and focus results immediately.
This will automatically launch the data processing with the IRAM  monitor.
Line 51: Line 45:
IDL >piic @monitorX # replace X with 1, 3, 2pf or 2m. 2pf is the fast queue to get the pointing and focus results immediately. This will automatically launch the data processing with the IRAM monitor.

__IDL: __
Line 53: Line 50:
Line 54: Line 52:
>nk_rta, "20201110s120"
Line 56: Line 53:
>nk_rta, "20201110sXXX"
Line 57: Line 55:
Test your vnc ! IRAM's howto for remote observations: [[http://mainwiki.iram.es/RemoteObservingGuide]]. __ '''Xephem'''__:
Line 59: Line 57:
>ssh -XY t22@mrt-lx3

>useNCS

>xephem &

>antennaCSDataStreamViewer &

Test your vnc ! IRAM's howto for remote observations: http://mainwiki.iram.es/RemoteObservingGuide.
Line 61: Line 68:
Line 66: Line 72:
3shifts of two people as follows (all times local time ie UTC+1h) :<<BR>>
-- 18h-23h30: Philippe + Hamza <<BR>>
-- 23h-4h30: Juan + Samuel (except night Sun15-Mon16 = Alessia takes Juan shift) <<BR>>
-- 4h-9h: Nicolas + Anaëlle
3shifts of two people as follows (all times local time ie UTC+1h) :<<BR>> -- 18h-23h30: Philippe + Hamza <<BR>> -- 23h-4h30: Juan + Samuel (except night Sun15-Mon16 = Alessia takes Juan shift) <<BR>> -- 4h-9h: Nicolas + Anaëlle
Line 73: Line 76:

* Ioannis/Bilal are the AoD, see IRAM's [[http://www.iram.es/IRAMES/mainWiki/AstronomersOnDutySchedule]].
 * Ioannis/Bilal are the AoD, see IRAM's http://www.iram.es/IRAMES/mainWiki/AstronomersOnDutySchedule.

NIKA2 technical run #46 / November 10-17, 2020

Back to the NIKA2 Run 46 main page

Goals

The overall goal is to complete the commissioning of the polarization capabilities of the NIKA2 camera, and make the first steps towards Science Verification. Following the data and their analysis from December 2018 and Feb 2020, the main priorities are:

- Confirmation of absolute angle calibration: on 3C286 + another QSO (chosen closer to dates depending on brightness/pol) also with XPOL observations, and on MWC349 (versus NOEMA?)

- XPOL sessions with Ioannis/Albrecht on 3C286 7h-9h on Thursday. If possible shared XPOL/NIKA2 on another QSO (3C454.3?) on Thursday evening ? - will adapt depending on weather/local conditions

- Stability of angle measurements and error bars with deep integrations on polarization standards, eg OMC1/DR21/Crab

- Evolution of Stokes Q/U rms with time with long integrations on known faint/extended sources to confirm tentative NEFDs obtained so far

- the two previous items will also allow to test our decorrelation methods developed for map-making on extended emission

- Get maps of polarization "leakages" using planets (Uranus) every night to evaluate the precision of correction in « real-conditions »

Sources

  • Visibilities of science verif sources:

nika2sv-sources-Nov2020.png

  • Visibilities of quasars:

nika2sv-qso-Nov2020.png

Tools during the run

PaKo:

ssh -XY t22@mrt-lx1

goNIKAnew

set dosubmit yes

PIIC NIKA2 data processing:

Connect to mrt-lx3:

>ssh -XY nikas-20@mrt-lx3

>cd ql

>piic @monitorX # replace X with 1, 3, 2pf or 2m. 2pf is the fast queue to get the pointing and focus results immediately. This will automatically launch the data processing with the IRAM monitor.

IDL:

ssh -XY observer@nika2-a

>idl

>nk_rta, "20201110sXXX"

Xephem:

>ssh -XY t22@mrt-lx3

>useNCS

>xephem &

>antennaCSDataStreamViewer &

Test your vnc ! IRAM's howto for remote observations: http://mainwiki.iram.es/RemoteObservingGuide.

Observers and Schedule

  • Telescope Schedule

  • Due to the Covid pandemic there's no travel at the telescope, observations will be on remote with the help of the remote AOD and Operators at the telescope. List of the remote observers and the shifts we agreed on:

3shifts of two people as follows (all times local time ie UTC+1h) :
-- 18h-23h30: Philippe + Hamza
-- 23h-4h30: Juan + Samuel (except night Sun15-Mon16 = Alessia takes Juan shift)
-- 4h-9h: Nicolas + Anaëlle

+ Daily meetings on zoom at 4pm.