Differences between revisions 104 and 108 (spanning 4 versions)
Revision 104 as of 2016-08-01 14:21:29
Size: 10404
Comment:
Revision 108 as of 2016-08-01 14:46:47
Size: 10657
Comment:
Deletions are marked like this. Additions are marked like this.
Line 32: Line 32:
A limited amount of time will be available in the upcoming winter semester 2016/17. See the call for proposals [[http://www.iram-institute.org/EN/content-page-169-7-57-169-0-0.html | here ]]. The above sensitivities shall be used, together with a factor for overheads (pointing, focus, slewing) of 2.0. A limited amount of time will be available in the upcoming winter semester 2016/17. See the call for proposals [[http://www.iram-institute.org/EN/content-page-169-7-57-169-0-0.html | here ]]. The above sensitivities shall be used, together with a conservative '''factor for overheads of 2.0''', which takes into account slewing, pointing, focus, skydips, beam measurements, photometry, tuning, etc.. The sensitivity at 1mm is obtained after combining the measurements of the two 1mm arrays. '''No polarization measurement is provided for the time being.'''

NIKA2 Homepage

NIKA2, the second generation New-IRAM-KID-Array, is a dual band camera operating simultaneously at 150 and 260 GHz. The instrument is based on large arrays of superconducting Kinetic Inductance Detectors (KID) operated at temperatures of 100mK. NIKA2 is built by an international consortium, led by the Institute Neel (Grenoble France). Successful installation took place in early October 2015. NIKA2's field of view has a 6.5arcmin diameter, with angular resolutions of 12 and 18 arcsec at 1 and 2 mm wavelengths respectively. NIKA2 is designed as a facility instrument which will remain at its present position for at least a decade. The instrument will allow to measure linear polarizations at 1.15 mm.

For September 2016, some important changes to the hardware are currently being prepared: the 150 GHz array, the dichroic frequency splitter, the lenses, and the cryostat window will be replaced and upgraded. In addition, several of the 20 readout electronics boards will be replaced with the last version. Commissioning will then continue well into the winter semester and NIKA2 shall be opened to the community in 2017.

NIKA2 in the web:


Overview

Some prelimiary characteristics of NIKA-2:

Band

Number of KIDs

Wavelength

Bandwidth

NEFD

HPBW

FoV

NIKA2 2 mm/150 GHz

1020

2.00 mm

125-170 GHz

20 mJy*s1/2

12"

6.5'

NIKA2 1 mm/260 GHz

2x1140

1.15 mm

240-280 GHz

30 mJy*s1/2

18"

6.5'

Call for proposals and time estimator

A limited amount of time will be available in the upcoming winter semester 2016/17. See the call for proposals here. The above sensitivities shall be used, together with a conservative factor for overheads of 2.0, which takes into account slewing, pointing, focus, skydips, beam measurements, photometry, tuning, etc.. The sensitivity at 1mm is obtained after combining the measurements of the two 1mm arrays. No polarization measurement is provided for the time being.


Publications

  • Instrument/detectors papers:
    • Catalano et al. 2016, The NIKA2 commissioning campaign: performance and first results, arxiv

    • Calvo et al. 2016, The NIKA2 instrument, a dual-band kilopixel KID array for millimetric astronomy, arxiv

    • Goupy et al. 2016, Microfabrication technology for large LEKID arrays : from NIKA2 to future applications, arxiv

    • Monfardini et al. 2014, Latest NIKA Results and the NIKA-2 Project, JLTP 176, 787, arxiv

    • Catalano et al. 2014, Performance and calibration of the NIKA camera at the IRAM 30 m telescope, A&A 569, A9, arxiv

    • Calvo et al. 2013, Improved mm-wave photometry for kinetic inductance detectors, A&A, 551, L12 ADS

    • Bourrion et al. 2012, NIKEL: Electronics and data acquisition for kilopixels kinetic inductance camera, Journal of Instrumentation, 7, 07, pp. 7014. arXiv

    • Monfardini et al. 2011, A Dual-band Millimeter-wave Kinetic Inductance Camera for the IRAM 30 m Telescope, ApJS, 194, 2, article id. 24. arXiv

    • Internal list of technical papers

  • Astronomical papers:
    • Adam, R., Comis, B., Bartalucci, I., et al. 2016, High angular resolution Sunyaev-Zel'dovich observations of MACS J1423.8+2404 with NIKA: Multiwavelength analysis, A&A, 586, 122 ADS

    • Adam, R., Comis, B., Macias-Perez, J.-F., et al, 2015, Pressure distribution of the high-redshift cluster of galaxies CL J1226.9+3332 with NIKA, A&A, 576, A12 ADS

    • Adam, R., Comis, B., Macias-Perez, J.-F, et al, 2014, First observation of the thermal Sunyaev-Zel'dovich effect with kinetic inductance detectors, A&A, 569, 66 ADS

  • Ph.D. thesis:
  • NIKA2 publications list maintained at IPAG


Technical Documentation

Go to the top


Technical runs to commission NIKA2

  • 1st test run of NIKA2: 29-October-2015 till 10-November-2015. Installation, cool down at the 30m, testing/debugging/developing. [= Run 13 of a NIKA instrument]

  • 2nd test run of NIKA2: 24-November-2015 till 02-December-2015. Continue tests started during run 1, in particular Beam maps and NEFD with the 13 NIKEL boards assembled the last days of run 1. [= Run 14 of a NIKA instrument]

  • 3rd test run of NIKA2: 12-January-2016 till 01-February-2016. Implementation of new NIKEL boards; the 20 data lines of NIKA2 are foreseen to be plugged simultaneously. With the 3 arrays fully read, continue and redo tests started with runs 1 & 2, in particular Beam maps and NEFD. [= Run 15 of a NIKA instrument]

  • 4th test run of NIKA2: 1-March-2016 till 15-March-2016. Continue tests started with previous runs, in particular investigate deeper beam patterns (XY focus, beam maps), synchronization, array 1 & 3 performances vs electronic boards, NEFD, mapping strategies. [= Run 16 of a NIKA instrument]

  • Dark run: 4-May-2016. Test sensitivity of NIKA2 to external electromagnetic perturbations, with the entrance window of the cryostat closed. [= Run 17 of a NIKA instrument]

  • 5th test run of NIKA2: 16-September-2016 till 11-October-2016. Upgrade NIKA2 with new dichroic, new corrugated lenses and window, new 2mm array, new NIKEL boards (get the 20 lines with homogeneous electronics, v3); redo better the tests started with previous runs (mostly beam maps in best weather conditions, but also various types of scan to investigate deeper beams and noise, synchronization, NEFD, skydips, mapping strategies, possibly polarization. [= Run 18 of a NIKA instrument]


Support teams

Go to top


Author: Israel Hermelo. Created: 5-Aug-2015. This page is maintained by PG, CK, SL and the NIKA team. Last update: 29-Jul-2016

Continuum/NIKA2/Main (last edited 2024-10-23 12:27:04 by CarstenKramer)