Welcome to the Calibration Working Group Page!

Telescope efficiencies and beam widths

Telescope efficiencies after painting the surface (valid from September 2024)

MSP, 01-Dec-2025. Computations done by JSG.

Freq (GHz)

ap. eff

err

Beff

S/TA*

Feff

84.25

0.62

0.01

0.82

5.9

0.95

98.25

0.59

0.01

0.78

6.2

0.95

100.25

0.58

0.01

0.76

6.4

0.95

143.25

0.47

0.02

0.62

7.7

0.93

157.25

0.43

0.02

0.57

8.4

0.93

159.25

0.43

0.02

0.56

8.4

0.93

215.75

0.45

0.02

0.59

8.0

0.92

229.75

0.42

0.02

0.56

8.5

0.92

231.75

0.43

0.02

0.57

8.3

0.92

252.57

0.36

0.02

0.47

9.9

 0.92

268.57

0.34

0.02

0.44

10.6

0.92

270.25

0.33

0.02

0.43

11.0

0.92

339.75

0.16

0.02

0.21

20.0

0.82

341.75

0.17

0.02

0.22

19.0

0.82

Notes about the data

Values for deriving the Efficiency using the Ruze formula

The efficiencies from the combination of E0 and E2 bands are systematically higher than those derived from the combination E1 and E3. The reason is not well known, but it is preferred to use two separate curves, with parameters given as:

  1. E0&E2: Ilum.eff: 0.65 (+/- 0.01), roughness: 71 (+/- 2) microns

  2. E1&E3: Ilum.eff: 0.57 (+/- 0.01), roughness: 78 (+/- 2) microns