Differences between revisions 4 and 5
Revision 4 as of 2009-07-08 16:07:59
Size: 900
Editor: gra-lx17
Comment:
Revision 5 as of 2009-07-08 16:13:16
Size: 1329
Editor: gra-lx17
Comment:
Deletions are marked like this. Additions are marked like this.
Line 27: Line 27:

----

=== PROBLEMS AND SOLUTIONS ===

This is a quick guide through normal problems that appeared in the past and the possible reasons and solutions.

 ||'''PROBLEM'''||'''REASON'''||'''SOLUTION'''||
 ||ABBA does not start getting data||Wobbler is not wobbling|| Ask the operator||
 ||ABBA does not start getting data||Wobbler works fine but the signal did not reach ABBA|| Check the cable connections with ABBA||
  

This document describe the checks and test that must be done before and during the Bolometer pool, as well as the frequency needed for these tests.

The tests are divided into different groups, as they supposed to be carried by different groups of the IRAM staff (operators, AoDs, or Rxs)

OPERATOR CHECKLIST

  • Bolometer temperature

AOD CHECKLIST

  • Teach the observers on the general aspects of the observation even they are expert MAMBO observers:

    • CookbookPako.

    • When to switch to heterodyne
    • What is a spiky scan
    • Not to open a second monitor at flexible@mrt-lx3:monitor/
  • Do absorber observations (AbsorberObs) when the weather is too bad even for heterodyne observations.

  • Do absorber observations (AbsorberObs) if the scans are too spiky

RXs CHECKLIST

  • Resistance
  • Check battery voltage


PROBLEMS AND SOLUTIONS

This is a quick guide through normal problems that appeared in the past and the possible reasons and solutions.

  • PROBLEM

    REASON

    SOLUTION

    ABBA does not start getting data

    Wobbler is not wobbling

    Ask the operator

    ABBA does not start getting data

    Wobbler works fine but the signal did not reach ABBA

    Check the cable connections with ABBA

BoloChkList (last edited 2011-05-30 15:13:12 by lt-ck)