Size: 1229
Comment:
|
Size: 1239
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 27: | Line 27: |
[[BR]] |
Tests performed during the heavy maintenance (2007.06.20)
Goals
Identify the origin(s) of the "acceleration" problem in MAMBO2
People
Pico Veleta: DJ, SL, SN, JP
Methods
Inclinometer installed on the Mambo2 platform
attachment:inclinometerPhoto.jpg
Results
- Inclinometer measurements for two on-off measurements with the Cascade and the Basic controller.
BR attachment:inclinometerBolo.jpg
- On-off measurements with the offsets in elevation: 360" (scan 47, Cascade) and 440" (scan 50, Basic)
BR Cascade controller attachment:scan47-elev-cascade.jpg
Basic controller attachment:scan50-elev-basic.jpg
- An extra weight was put on the bolometer platform (scan 51)
attachment:scan51.jpg
- Measurements of electrical peak with the oscilloscope during an on-off measurements with the offsets in elevation (scan 53).
No correlation was found between the beginning of the scans where the extra noise peaks appeared and the electric activity. A peak frequency of 5 sec was observed but which may be related to the air conditioned system.