Back to the NIKA2 Run 80 main page
Run80 data processing
Here we include the preliminary data reduction results of the re-commissioning NIKA2 run 80, as obtained at the telescope during this week (2026/03/24-31).
Focus difference between the three arrays
As of 2026/03/25 @01:25 UT.
The focus difference Ar1-Ar2 is roughly +1.00 mm.
The focus difference Ar3-Ar1 is roughly -0.05 mm.
Focus sequences
Scan nr
Target
Ar2
Ar1
Ar3
Polarized?
Notes
20260324s153-157
Uranus
0.27
1.25
1.2
no
Started at 1.0 mm; tadadada; Ar2 good fit; Ar1 and Ar3 fit is marginal
158-162
Uranus
out
1.3
1.25
no
Started at 1.5 mm; Ar1 perfect fit; Ar2 out of range
163-167
Uranus
0.28
out
out
no
Started at 0.5 mm; Ar2 perfect fit; Ar1 out of range
171-175
Uranus
out
1.22
1.18
no
started at 1.5 mm; Ar1 perfect fit; Ar2 out of range
206-210
0851+202
out
1.36
1.31
no
Started at 1.4 mm; Ar1 and Ar3 perfect fit; Ar2 out of range
Beam maps analysis
On 2026/03/24 we took