== NIKA2 focus test: August 30, 2026 ==

 * Today Mixing Chamber temperature is T_MC ~187 mK and P101 ~1455 mbar. We proceed with focus tests.

 * Opacity all along the shift: ~0.4; peak-to-peak variations at 2 mm: ~ 5 Jy/beam. Max. wind speed around 3 m/s.

 * Observing 3C273 from El. ~40 deg to ~27 deg.

 * DAQ started at 18h05LT. NIKA2 tuning at 63 deg in elevation; bad KIDs (NIKA2 window and vertex open): 27/1000, 9/574, 13/749 (Ar1, Ar2, Ar3). Traces look fine with somewhat more structure for Ar1.


 |||||||||||||| Focus sequences ||
 || Scan nr || Target || Ar2 || Ar1 || Ar3 || Polarized? || Notes ||
 || 20260829s155-159 || 3C279 || (-0.55) || 0.5 || 0.45 || no || Started at 0.4 mm; Ar2 marginal (fit from FWHM only) ||
 || 20260829s160-164 || 3C279 || (-0.63) || 0.87|| 0.8 || no || Started at 0.6 mm; Ar2 marginal (fit from FWHM only) ||
 || 20260829s165-169 || 3C279 || -0.6 || (0.76) || (0.67) || no || Started at 0.0 mm; Ar2 good; (Ar1 and Ar3 gFit peak only) ||
 || 20260829s170-174 || 3C279 || -0.43 || 0.7|| out || no || Started at 0.1 mm; Ar2 good ||
 || 20260829s175-179 || 3C279 || -0.46|| 0.55 || 0.43 || no || Started at 0.2 mm; Ar2 good and reasonable Ar1 & Ar3 (except for FWHM fitting) ||
 || 20260829s181-185 || 3C279 || (-0.7) || out || out || no || Started at 0.3 mm; Ar2 marginal (fit from FWHM only) ||


 * '''Focus offsets: Ar1-Ar2 = 1.16 mm, Ar3-Ar1 = -0.08 mm'''.

Back to the NIKA2 Run 80 main page

Run80 data processing

Contributions by: Stefano Berta, Kaiyi Du.

Here we include the preliminary data reduction results of the re-commissioning NIKA2 run 80, as obtained at the telescope during this week (2026/03/24-31).

Focus difference between the three arrays

As of 2026/03/25 @01:25 UT.
The focus difference Ar1-Ar2 is roughly +1.00 mm.
The focus difference Ar3-Ar1 is roughly -0.05 mm.

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260324s153-157

    Uranus

    0.27

    1.25

    1.2

    no

    Started at 1.0 mm; tadadada; Ar2 good fit; Ar1 and Ar3 fit is marginal

    158-162

    Uranus

    out

    1.3

    1.25

    no

    Started at 1.5 mm; Ar1 perfect fit; Ar2 out of range

    163-167

    Uranus

    0.28

    out

    out

    no

    Started at 0.5 mm; Ar2 perfect fit; Ar1 out of range

    171-175

    Uranus

    out

    1.22

    1.18

    no

    started at 1.5 mm; Ar1 perfect fit; Ar2 out of range

    206-210

    0851+202

    out

    1.36

    1.31

    no

    Started at 1.4 mm; Ar1 and Ar3 perfect fit; Ar2 out of range

Ar2 focus, scans 153-157 Ar1 focus, scans 153-157 Ar3 focus, scans 153-157

Ar2 focus, scans 163-167 Ar1 focus, scans 158-162 Ar3 focus, scans 158-162

Ar1 focus, scans 206-210 Ar3 focus, scans 206-210

Beam maps analysis

We have a new Ar3 and we need to characterize its geometry and its flat field. To this aim, on 2026/03/24 we took two beam maps focused on Ar1 (scans 20260324s169 and 177). The idea and hope is that the focus of Ar3 is roughly the same of that of Ar1, thanks to the March 10 intervention, and these beam maps will be good for our purpose.

We reduce the beam maps during the night between 2026/03/24 and 25.
Ar2 is out of focus and in order to be able to reduce it, we need to relax completely the constraints on its beam size and shape.
Ar1 is well on focus. The best beam map is 177. The other (169) has some problems at the lower edge for unknown reasons.
The Ar3 focus is decent. The array is missing Box S, as already known, and also several KIDs in Boxes M, N O (supposedly).

Below here you can see the geometry of the three Arrays as derived from the average of these two beam maps.

Ar2 beam maps 169 and 177 Ar1 beam maps 169 and 177 Ar3 beam maps 169 and 177

Study of the Ar1 and Ar2 beams at different focus values

On 2026/03/25, we carried out a series of calib_1scan with different focus values, starting from the Ar1 optimal focus to the Ar2 optimal focus, in steps of 0.2 mm. The aim was to study the change of MB flux (because the CAL is based on main beams), % of flux in the side lobes of the beam, and FWHM of the minor/major axes of the beam, as a function of focus (distance from the optimal position). Below here you find a table that summarizes our measurements and a series of plots produced by the PIIC monitors for Ar1 and Ar2.

Note, however that polarimetry observations would at best be carried out at the Ar1+3 optimal focus (rather than at a compromise focus) because of the criticality of the IP correction.

Studying this table, we have the suspicion that we need to perform a new lateral focus (XY). We are considering to postpone it to Sep-Oct, after a possible new NIKA2 hardware intervention.

  • Study of the NIKA2 beams (TP, point-like target)

    General

    Ar1

    Ar2

    Scan nr

    El. [deg]

    Target

    Z Focus [mm]

    Notes

    MB flux [mJy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    MB flux [mJy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    243

    48.8

    3C273

    1.35

    Ar1 focus

    4.85

    7.4%

    11.40

    11.86

    6.96

    8.5%

    17.72

    20.47

    245

    50.1

    3C273

    1.15

    Ar1-0.2 mm

    4.32

    9.5%

    11.43

    12.84

    7.19

    7.7%

    17.54

    19.49

    247

    51.8

    3C273

    0.95

    Ar1-0.4 mm

    4.07

    11.2%

    11.61

    13.06

    7.21

    7.8%

    17.24

    19.60

    249

    52.9

    3C273

    0.75

    Ar1-0.6 mm

    3.77

    16.0%

    12.44

    15.67

    7.51

    7.2%

    17.19

    18.84

    251

    53.7

    3C273

    0.55

    Ar1-0.8 mm

    3.62

    19.8%

    14.78

    21.86

    7.47

    7.3%

    17.34

    18.56

    253

    54.3

    3C273

    0.35

    +/- Ar2 focus

    3.64

    28.1%

    17.40

    29.17

    7.34

    8.0%

    17.59

    18.59

    NOTE: the focus values listed here do already include the -0.2 adjustment for the curved focal surfaces

Beam analysis, scan 243, Ar1 Beam analysis, scan 243, Ar2

Beam analysis, scan 245, Ar1 Beam analysis, scan 245, Ar2

Beam analysis, scan 247, Ar1 Beam analysis, scan 247, Ar2

Beam analysis, scan 249, Ar1 Beam analysis, scan 249, Ar2

Beam analysis, scan 251, Ar1 Beam analysis, scan 251, Ar2

Beam analysis, scan 253, Ar1 Beam analysis, scan 253, Ar2

New Study of the Ar1, Ar3 and Ar2 beams at different Z focus values

2026/03/28-29 Following the request by Carsten, we repeat the experiment. Carsten noted that the best Ar2 beam is not at the best Ar2 focus, but a bit far from it. Several factors might be causing this:

  • first of all this seems to be an indication of the need of a new lateral (XY) focus. We have discussed it here and we have decided to wait for October, because a) there won;t be any science observations meanwhile; b) there will hopefully be another NIKA2 hardare intervention to fix the difference of focus between Ar13 and Ar2, that seems to be caused again by the dichroic that is bending (a lot).
  • during the whole campaign the best Z focus might have slightly changed, because of a change of Elevation and of other conditions such as temperature etc., although such change is surely not as big at 0.6 mm.

Check the table below: the Ar1 and Ar3 MB fluxes increase when they should be decreasing! Are we seeing the QSO that is bursting? Or is it the wind? Or the change of Elevation (I hope not!)

  • Study of the NIKA2 beams (TP, point-like target) using calib_1scan

    General

    Ar2

    Ar1

    Ar3

    Extras

    Scan nr

    El. [deg]

    Target

    Z Focus [mm]

    Notes

    MB flux [mJy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    MB flux [mJy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    MB flux [mJy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    windy records

    20260328s165

    38.9

    3C279

    1.59

    Ar1 focus

    12.34

    9.4%

    17.35

    24.72

    8.51

    6.3%

    11.52

    12.10

    11.32

    7.5%

    11.37

    12.29

    --

    167

    40.6

    3C279

    1.49

    Ar1-0.1 mm windy

    12.32

    9.8%

    17.25

    25.01

    8.17

    6.5%

    11.82

    13.64

    10.79

    7.8%

    11.78

    13.23

    5.5%

    169

    41.9

    3C279

    1.39

    Ar1-0.2 mm windy

    12.77

    9.5%

    17.03

    25.02

    8.39

    7.1%

    11.85

    13.44

    10.96

    7.9%

    11.73

    13.07

    8.9%

    171

    43.1

    3C279

    1.39 !

    Ar1-0.3 mm windy

    14.78

    9.6%

    16.81

    25.82

    10.98 (?)

    7.8%

    11.80

    14.06

    14.23 (?)

    8.2%

    11.84

    13.52

    9.0%

    173

    44.2

    3C279

    1.29

    Ar1-0.4 mm windy

    16.27

    10.8%

    17.71

    26.68 (?)

    14.18

    9.2%

    12.61

    17.07

    17.56

    9.2%

    12.63

    16.49

    7.5%

    175

    45.2

    3C279

    1.19

    Ar1-0.5 mm

    17.18

    9.3%

    17.31

    24.85

    14.83

    8.4%

    11.62

    17.56

    18.45

    8.8%

    11.80

    16.16

    --

    177

    45.9

    3C279

    1.59 !

    Ar1 focus !

    16.7

    11.2%

    17.05

    29.45

    15.56

    9.1%

    12.82

    13.64

    18.75

    8.4%

    12.31

    13.55

    --

    20260329s2

    46.4

    3C279

    1.09

    Ar1-0.6 mm

    18.12

    10.3%

    17.85

    25.41

    17.26

    10.7%

    11.86

    21.65

    20.12

    10.4%

    11.96

    18.95

    --

    4

    3C279

    1.59 !

    Ar1 focus ! windy

    17.50

    13.6%

    17.46

    34.04

    17.19

    13.2%

    13.92

    15.56

    19.85

    11.9%

    12.90

    15.72

    14.7%

    This last scan would have been on ar1 focus! We stop. Too much wind. We will have to repeat this exercise on a calm night, possibly wher the source is culminating, so to minimize the changes of Elevation between scans.

    6 n/a

    3C279

    0.99

    Ar1-0.7 mm

    8 n/a

    3C279

    0.89

    Ar1-0.8 mm

    10 n/a

    3C279

    0.79

    Ar1-0.9 mm

    12 n/a

    3C279

    0.69

    Ar2 focus

    14 n/a

    3C279

    0.59

    Ar2 focus

    16 n/a

    3C279

    0.59

    Ar2 focus

    NOTE 1: the focus values listed here do already include the -0.2 adjustment for the curved focal surfaces

    NOTE 2: the Ar3 absolute flux calibration is incorrect because no DAFs CAL are available yet

    NOTE 3: focus performed in scans 159-163, Ar1=1.59; Ar3=1.54; Ar2=0.59

    NOTE 4: windy records = percenteage of records rejected because of too large tracking deviations

Third (and last attempt to study of the Ar1, Ar3 and Ar2 beams at different Z focus values

2026/03/30 I try again. The wind has decreased significantly. This time I use 3C273 (much more stable than 3C279). I do it close to culmination, such that the change of Elevation is minimized. I also monitor the P100 information, i.e. the behaviour of the main dish / back structure temperature sensors. In fact, it is known that these sensors suffer humidity and condensation of the water that accumulates into the back structure. When they "get wet", the temperature difference in the back structure has some peaks and the temperature compensation of the focus goes bananas.

The procedure is as in the two previous attempts:

  • pointing, focus, to determine the best focus values
  • pointing, calib_1sca
  • starting at the Ar1 focus and decresing to the Ar2 focus, in steps of 0.2 mm (as on 2026/03/25; instead of 0.1 mm as yesterday)

    Study of the NIKA2 beams (TP, point-like target) using calib_1scan

    General

    Ar2

    Ar1

    Ar3

    Scan nr

    Tapas El. [deg]

    Target

    Z Focus [mm]

    Notes

    windy records

    T diff bck struc [C]

    T diff quadripod [C]

    Z axis corr by T [um]

    MB flux [mJy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    MB flux [mJy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    MB flux [mJy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    20260330s11

    54.01

    3C273

    1.05

    Ar1 focus

    --

    -1.35

    -0.41

    -1063

    7.02

    12.8%

    18.07

    26.48

    5.38

    7.0%

    11.50

    12.32

    6.33

    8.5%

    11.48

    12.50

    13

    53.37

    3C273

    0.85

    Ar1-0.2

    --

    -0.94

    -0.36

    -740

    7.05

    13.4%

    18.17

    28.56

    5.43

    6.9

    11.69

    12.26

    6.3

    8.3%

    11.25

    12.57

    15

    52.45

    3C273

    0.65

    Ar1-0.4

    --

    -0.98

    -0.36

    -759

    7.49

    10.5%

    17.53

    23.03

    5.44

    7.6%

    11.29

    12.67

    6.39

    9.0%

    11.18

    12.58

    17

    51.44

    3C273

    0.45

    Ar1-0.6

    --

    -0.86

    1.14

    -966

    7.82

    9.3%

    17.54

    21.00

    5.00

    10.8%

    11.28

    14.51

    5.95

    11.4%

    11.31

    13.69

    19

    50.30

    3C273

    0.25

    Ar1-0.8

    --

    -1.42

    -0.18

    -1170

    8.06

    7.6%

    17.78

    19.17

    4.50

    16.8%

    12.47

    18.93

    5.15

    16.6%

    12.37

    17.13

    21

    48.88

    3C273

    0.05

    Ar1-1.0 = Ar2 focus

    --

    -1.50

    -0.23

    -1228

    8.12

    6.7%

    17.71

    18.79

    4.43

    21.9%

    15.50

    24.61

    5.04

    21.1%

    14.66

    22.37

    23

    47.49

    3C273

    -0.15

    Ar1-1.2

    --

    -1.53

    -0.27

    -1245

    7.99

    7.7%

    17.53

    10.12

    4.66

    22.0%

    19.57

    29.36

    5.17

    24.7%

    18.30

    26.48

    25

    45.97

    3C273

    1.05

    Ar1 focus

    --

    -1.47

    -0.15

    -1219

    7.11

    8.4%

    17.96

    21.77

    5.48

    6.5%

    11.24

    11.74

    6.46

    6.5%

    11.02

    12.09

    NOTE 1: the focus values listed here do already include the -0.2 adjustment for the curved focal surfaces

    NOTE 2: the Ar3 absolute flux calibration is incorrect because no DAFs CAL are available yet

    NOTE 3: focus performed in scans 4-8, Ar1=1.05; Ar3=1.05; Ar2=out of range

    NOTE 3b: focus checked again at the end of the exercise, in scans 26-30, Ar1=1.05; Ar3=1.03; Ar2=out of range; good; the focus kept stable along the whole test.

    NOTE 4: windy records = percentage of records rejected because of too large tracking deviations

    NOTE 5: the Temperatures of the back structure etc. are recorded at the start of the calib_1scan

Test of focus difference between the three arrays after cryostat total warm-up and cool-down cycle (April 24, 2026)

AoD: Ioannis

Outline of test slot T21-25:

  • Started with the test on-time (21:00 LT)
  • Tuning instrument with cryostat window closed (run92.ini). Bad kids 12/5/11 for Ar1/Ar2/Ar3. No bumps in DAQ traces for all arrays, instrument looks in very good condition.
  • Tuning instrument with cryostat window open. Bad kids 47/13/28 for Ar1/Ar2/Ar3. No bumps in DAQ traces for all arrays, instrument looks in very good condition.
  • Pointing and several focus sequences on 3C273. Stability at the beginning at +/- 3 Jy/beam at 2mm.
  • Going to 3C279 for another focus test. Stability gets worse at +/- 7-10 Jy/beam. Opt focus for Ar2 and beam is 16.98x18.42
  • Later stability improved again at +/- 2-3 Jy/beam
  • Back to 3C273 for the calib_1scan series test at different focus positions. Results listed below. Consecutive scans showed strangely a pointing disagreement between the arrays with 2-3 arcsec differences in both Az and El.
  • Conditions get much poorer at the end with +/- 20 Jy/beam (2mm)

As of 2026/04/25 @22:00 UT.
The focus difference Ar1-Ar2 is roughly +1.20 mm.
The focus difference Ar3-Ar1 is roughly -0.05 mm.

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260425s35-39

    3C273

    0.81

    out

    out

    no

    Started at 1.0 mm; Ar2 good fit; Ar1 and Ar3 fit is out

    40-44

    3C273

    out

    1.97

    1.93

    no

    Started at 2.0 mm; Ar1 and Ar3 good fit; Ar2 out of range

    45-49

    3C273

    0.91

    out

    out

    no

    Started at 1.4 mm to catch all 3 focus positions but just missed Ar1 and Ar3

    51-55

    3C279

    out

    out

    out

    no

    started at 1.6 mm to catch all 3 focus positions but all arrays out of range

    56-60

    3C279

    0.79

    out

    out

    no

    Started at 1.0 mm; Ar2 perfect fit; Ar1 and Ar3 out of range

    61-65

    3C279

    out

    2.03

    1.97

    no

    Started at 2.0 mm; Ar1 and Ar3 good fit; Ar2 out of range

    Study of the NIKA2 beams (TP, point-like target) using calib_1scan

    General

    Ar2

    Ar1

    Ar3

    Scan nr

    Tapas El. [deg]

    Target

    Z Focus [mm]

    Notes

    windy records

    T diff bck struc [C]

    T diff quadripod [C]

    Z axis corr by T [um]

    MB flux [Jy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    MB flux [Jy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    MB flux [Jy]

    Side lobes %

    FWHM min [arcsec]

    FWHM max [arcsec]

    20260425s67

    49.58

    3C273

    2.03

    Ar1 focus

    --

    -2.38

    +0.33

    -2091

    7.74

    11.6%

    18.24

    23.26

    4.26

    11.4%

    11.53

    11.68

    4.35

    12.3%

    11.10

    12.68

    69

    50.49

    3C273

    1.63

    Ar1-0.4

    --

    -2.39

    +0.29

    -2091

    8.30

    9.2%

    17.66

    20.77

    3.79

    14.6%

    11.96

    12.84

    3.99

    14.3%

    11.13

    14.28

    71

    51.26

    3C273

    1.23

    Ar1-0.8

    --

    -2.28

    +0.39

    -2018

    8.31

    8.1%

    17.65

    19.76

    3.13

    20.4%

    13.68

    17.29

    3.35

    20.9%

    12.47

    18.40

    73

    52.08

    3C273

    0.83

    Ar1-1.2 ~ Ar2 focus

    --

    -2.32

    +0.34

    -2042

    8.47

    8.6%

    17.77

    19.11

    2.93

    32.3%

    17.11

    22.32

    3.26

    29.0%

    16.20

    22.54

    NOTE 1: the focus values listed here do already include the -0.2 adjustment for the curved focal surfaces

    NOTE 2: windy records = percentage of records rejected because of too large tracking deviations

    NOTE 3: the Temperatures of the back structure etc. are recorded at the start of the calib_1scan

Ar2 focus, scans 56-60 Ar1 focus, scans 61-65 Ar3 focus, scans 61-65

Ar2 DAQ traces Ar1 DAQ traces Ar3 DAQ traces

Testing focus difference between the arrays: May 19, 2026

  • AB: thanks to Brisa Mancillas and the current Team of the heterodyne pool week for this opportunity.
  • Cryostat has been cold since April 24, 2026. During the morning maintenance slot, Dave noticed a relatively wide bump at ~1.4 Hz in the noise traces of array 1, with the window closed.
  • Starting the preparation for the focus test at 21:00 (LT); anomalous refraction/unstable atmosphere during the preceding hours; tau_225GHz~0.25; pretty clear sky, no wind. DAQ started at 21:15 just after finishing an EMIR scan; window closed, bad KIDs (ar1, 2, 3): 10/1000, 7/574, 9/749. Noise traces:

Ar2 DAQ traces, closed Ar1 DAQ traces, closed Ar3 DAQ traces, closed

  • DAQ restarted at 21:25; window open, blank sky, bad KIDs (ar1, 2, 3): 17/1000, 7/574, 17/749. Noise traces:

Ar2 DAQ traces, open Ar1 DAQ traces, open Ar3 DAQ traces, open

  • First pointing on 1226+023 (3C273) @21:33, El. ~51.5 deg.; stability: p2p var. ~5 Jy/beam (2 mm); superb tracking. Five focus sequences. Not so stable in the middle of the session (p2p var. up to ~15 Jy/beam, 2 mm). Switched to 3C279 in the last part. Coming back to EMIR at ~22:35. Ideally, the next test -maybe a repetition of this one for confirming results, before the planned partial warm-up (TBD)- should be carried out just before midnight, so that the telescope is more relaxed. Focus offsets: Ar1-Ar2 = 1.01 mm, Ar3-Ar1 = -0.03 mm.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260519s234-238

    3C273

    0.23

    (1.41)

    (1.43)

    no

    Started at 1.0 mm; Ar2 good fit; Ar1 and Ar3 fit from (FWHM's only), peak fits are bad

    239-243

    3C273

    (0.58)

    1.53

    1.54

    no

    Started at 1.45 mm; Ar2 fit from (FWHM's only), peak fits are bad; Ar1 and Ar3 good fit

    244-248

    3C273

    0.56

    out

    out

    no

    Instabilities increasing; started at 0.3 mm; Ar2 good fit; Ar1 and Ar3 very bad

    250-254

    3C279

    out

    1.59

    1.53

    no

    Started at 1.7 mm; Ar2 fit from FWHM is bad; Ar1 and Ar3 good fit

    255-259

    3C279

    0.55

    out

    out

    no

    Started at 0.6 mm; Ar2 good fit; Ar1 and Ar3 very bad

  • Selected best-fit plots:

Ar2 focus, scans 244-248 Ar1 focus, scans 239-243 Ar3 focus, scans 239-243

Ar2 focus, scans 255-259 Ar1 focus, scans 250-254 Ar3 focus, scans 250-254

Testing focus difference between the arrays: May 20, 2026

  • AB: Cryostat cold since April 24, 2026. As a side note, Dave changed to the 2nd trap in the afternoon. Checking yesterday's results just after midnight, hopefully with a more relaxed telescope and stable atmosphere.
  • DAQ started at 22:55 (LT), bad KIDs (ar1, 2, 3): 21/1000, 7/574, 13/749. Mild wind (~8 m/s max.). Pointing on 3C279, El. ~47 deg. Excellent tracking and stability throughout the session (~2 mJy/beam 2mm): ended at ~00:10. Focus offsets: Ar1-Ar2 = 1.15 mm, Ar3-Ar1 = -0.02 mm.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260520s186-190

    3C279

    0.72

    out

    out

    no

    Started at 0.5 mm; Ar2 good fit; Ar1 and Ar3 bad

    191-195

    3C279

    (0.89)

    1.87

    1.83

    no

    Started at 1.7 mm; Ar2 fit from (FWHM's only), peak fits are bad; Ar1 and Ar3 good

    196-200

    3C279

    0.64

    out

    out

    no

    Started at 0.85 mm; Ar2 good fit; Ar1 and Ar3 bad

    201-205

    3C279

    (0.96)

    1.82

    1.81

    no

    Started at 1.9 mm; Ar2 fit from (FWHM's only), peak fits are bad; Ar1 and Ar3 good

    206-210

    3C279

    0.6

    out

    out

    no

    Started at 0.7 mm; Ar2 good fit; Ar1 and Ar3 bad

    211-215

    3C279

    (0.89)

    1.71

    1.69

    no

    Started at 1.8 mm; Ar2 fit from (FWHM's only), peak fits are bad; Ar1 and Ar3 good

  • Selected best-fit plots:

Ar2 focus, scans 196-200 Ar1 focus, scans 201-205 Ar3 focus, scans 201-205

Ar2 focus, scans 206-210 Ar1 focus, scans 211-215 Ar3 focus, scans 211-215

Testing focus difference between the arrays: May 21, 2026

  • DAQ started at 22:40 (LT), window closed, bad KIDs (ar1, 2, 3): 16/1000, 9/574, 11/749. Noise traces:

Ar2 DAQ traces, closed Ar1 DAQ traces, closed Ar3 DAQ traces, closed

  • DAQ restarted at 23:00 (LT), window open, bad KIDs (ar1, 2, 3): 14/1000, 7/574, 14/749. Low wind speed (<3 m/s max.), tau_225GHZ ~0.2. Noise traces:

Ar2 DAQ traces, open Ar1 DAQ traces, open Ar3 DAQ traces, open

  • First pointing on 3C279, clear sky, excellent tracking, stable (<1-4 mJy/beam throughout the shift). Starting focus sequences. Ended at 00:25 (LT). Focus offsets: Ar1-Ar2 = 1.17 mm, Ar3-Ar1 = -0.05 mm.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260521s290-294

    3C279

    0.71

    out

    out

    no

    Started at 0.5 mm; Ar2 good fit; Ar1 and Ar3 bad

    295-299

    3C279

    (0.92)

    1.81

    1.78

    no

    Started at 1.8 mm; Ar2 fit from (FWHM's only), peak fits are bad; Ar1 and Ar3 good

    301-305

    3C273

    0.72

    out

    out

    no

    Started at 0.7; Ar2 good fit; Ar1 and Ar3 bad

    306-310

    3C273

    0.79

    1.99

    1.94

    no

    Started at 1.6; reasonable fits

    311-315

    3C273

    out

    1.79

    1.77

    no

    Started at 1.9; Ar2 marginal, Ar1 and Ar3 good; very stable

    316-320

    3C273

    0.6

    out

    out

    no

    Started at 0.8; Ar2 good fit; Ar1 and Ar3 bad; very stable

    321-325

    3C273

    out

    1.87

    1.83

    no

    Started at 1.9; Ar1 and Ar3 good

  • Selected best-fit plots:

Ar2 focus, scans 306-310 Ar1 focus, scans 306-310 Ar3 focus, scans 306-310

Ar2 focus, scans 316-320 Ar1 focus, scans 311-315 Ar3 focus, scans 311-315

Cross-talking of Ar3

2026/05 Kaiyi started the cross-talk analysis of run 80. It seems that the new Ar3 has quite a number of cross-talking KIDs. Here follows an example of 42 KIDs, showing that several are affected (at least 16/42 in this case). The analysis is ongoing and the list of cross-talking KIDs will be updated in the PIIC DAFs as soon as we have converged on the final identification.

New Ar3 cross-talk analysis New Ar3 cross-talk analysis

Testing focus difference between the arrays: June 5, 2026

  • First focus test after the partial warm-up of May 22nd. Cryostat in good shape, DAQ started earlier, window closed, bad KIDs (ar1, 2, 3): 14/1000, 9/574, 7/749. Nice noise traces.
  • DAQ re-started at 23:55 (LT), window open, bad KIDs (ar1, 2, 3): 28/1000, 4/574, 14/749. Mild wind (~7-8 m/s max.), tau_225GHz ~0.4-0.5. Pointing on 3C273, El. ~43 deg. Excellent tracking and stability along the session (<2 mJy/beam, 2mm): ended at 01:20. Focus offsets: Ar1-Ar2 = 1.13 mm, Ar3-Ar1 = -0.05 mm.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260605s300-304

    3C273

    0.55

    (1.49)

    --

    no

    Started at 1.0 mm; Ar2 good fit; Ar1 fit from (FWHM's only); Ar3 bad (4/5 scans only)

    20260605s305-309

    3C273

    (0.68)

    1.65

    1.61

    no

    Started at 1.6 mm; Ar2 fit from (FWHM's only, marginal), peak fits are bad; Ar1 and Ar3 good

    20260605s310-314

    3C273

    (0.89)

    1.7

    1.64

    no

    Started at 1.8 mm; Ar2 fit from (FWHM's only, marginal), peak fits are bad; Ar1 and Ar3 good

    20260605s315-319

    3C273

    0.54

    (1.47)

    out

    no

    Started at 1.0 mm; Ar2 good fit; Ar1 fit from (FWHM's only, marginal); Ar3 bad

    20260605s320-324

    3C273

    out

    1.66

    1.61

    no

    Started at 1.9 mm; Ar2 bad; Ar1 and Ar3 good

    20260605s325-329

    3C273

    0.38

    out

    out

    no

    Started at 0.8 mm; Ar2 good fit; Ar1 and Ar3 bad

    20260605s330-334

    3C273

    out

    1.52

    1.46

    no

    Started at 1.8 mm; Ar2 bad; Ar1 and Ar3 good

Testing focus difference between the arrays: June 9, 2026

  • Second focus test after the partial warm-up of May 22nd.
  • Test started late, after 22:15 local time due to strong atmospheric instabilities earlier.
  • Cryostat in good shape, DAQ started with window closed, bad KIDs (ar1, 2, 3): 15/5/9. Nice noise traces. Then retuned with window open, bad KIDs (ar1, 2, 3): 17/4/13. Noise traces still nice. See screenshots below.
  • Low wind (~1-3 m/s max.), tau_225GHz ~0.25-0.32. Pointing on 3C279, El. ~50 deg. Excellent tracking and good stability along the session (~2-5 Jy/beam @ 2mm): ended at 23:40 local time. Focus offsets: Ar1-Ar2 = 1.17 mm, Ar3-Ar1 = -0.05 mm.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260609s205-209

    3C279

    0.24

    1.41

    1.38

    no

    Started at 1.0 mm; Ar2, Ar1 and Ar3 just acceptable fits, a bit on the edge

    20260609s210-214

    3C279

    0.22

    out

    out

    no

    Started at 0.5 mm; Ar2 good fit; Ar1 and Ar3 bad

    20260609s215-219

    3C279

    out

    1.41

    1.36

    no

    Started at 1.6 mm; Ar2 fit bad; Ar1 and Ar3 good

    20260609s220-224

    3C279

    0.20

    out

    out

    no

    Started at 0.3 mm; Ar2 good fit; Ar1 and Ar3 bad

    20260609s225-229

    3C279

    out

    1.36

    1.30

    no

    Started at 1.4 mm; Ar2 bad; Ar1 and Ar3 good

  • DAQ started at 22:15 (LT), window closed, bad KIDs (ar1, 2, 3): 15/1000, 5/574, 9/749. Noise traces:

Ar2 DAQ traces, closed Ar1 DAQ traces, closed Ar3 DAQ traces, closed

  • DAQ restarted at 22:45 (LT), window open, bad KIDs (ar1, 2, 3): 17/1000, 4/574, 13/749. Low wind speed (<3 m/s max.), tau_225GHZ ~0.27. Noise traces:

Ar2 DAQ traces, open Ar1 DAQ traces, open Ar3 DAQ traces, open

Testing focus difference between the arrays: July 8, 2026

  • First focus test after the total warm-up of June 12th. Cryostat is cold since July 2nd (telescope's heavy maintenance in the middle).
  • At the beginning, tau_225GHz ~0.3; ambient temperature: 18.5 C. Homology corrections went crazy with the first scan. Frédéric fixed it. Pointing on 3C273, El. ~50 deg. Excellent tracking and good stability along the session (~1-4 Jy/beam @ 2mm): ended at ~21h (sunset: 21:38). Focus offsets: Ar1-Ar2 = 1.27 mm, Ar3-Ar1 = -0.03 mm.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260708s253-257

    3C273

    --

    0.89

    0.86

    no

    Started at 1.0 mm; Ar2 marginal fit, Ar1 and Ar3 good

    20260708s258-262

    3C273

    -0.37

    out

    out

    no

    Started at 0.2 mm; Ar2 good, Ar1 and Ar3 out; repointing on Ar2 again (s263) after setting focus

    20260708s265-268

    3C273

    -0.38

    out

    out

    no

    Started at 0. mm; confirming focus for Ar2; Ar1 and Ar3 out, Ar2 good

    20260708s269-273

    3C273

    out

    0.89

    0.85

    no

    Started at 1.1 mm; Ar2 quite marginal, Ar1 and Ar3 good; even more stable in the l.o.s.

    20260708s274-278

    3C273

    -0.38

    out

    out

    no

    Started at -0.15 mm; Ar2 good, Ar1 and Ar3 out

    20260708s279-283

    3C273

    out

    0.95

    0.93

    no

    Started at 1.2 mm; Ar2 out, Ar1 and Ar3 good

    20260708s284-288

    3C273

    -0.34

    out

    out

    no

    Started at -0.2 mm; Ar2 good, Ar1 and Ar3 out

    20260708s289-293

    3C273

    out

    0.92

    0.89

    no

    Started at 1.25 mm; Ar2 out, Ar1 and Ar3 good

  • Selected focus fit plots:

Ar2 focus, scans 284-288 Ar1 focus, scans 279-283 Ar3 focus, scans 279-283

  • DAQ started at 20:50 (LT), window (tightly) closed, telescope stopped, mild wind, bad KIDs (ar1, 2, 3): 14/4/7. Some correlated noise is observed below ~1 Hz:

Ar2 noise traces, window closed Ar1 noise traces, window closed Ar3 noise traces, window closed

  • DAQ restarted at ~21:10, window open, bad KIDs (ar1, 2, 3): 24/6/20. Sampled spectra, El. ~70 deg.:

Ar2 noise traces, window open Ar1 noise traces, window open Ar3 noise traces, window open

Testing focus difference between the arrays: July 9, 2026

  • At the beginning (19:05 LT), tau_225GHz ~0.35 (80% R.H); ambient temperature: ~16 C. Wind speed (max.) ~9 m/s. Pointing on 3C273, El. ~50 deg. Good tracking, p2p ~3-10 Jy/beam @ 2mm over the shift: ended at 21:00 (sunset: 21:37). Focus offsets: Ar1-Ar2 = 1.14 mm, Ar3-Ar1 = -0.04 mm.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260709s261-265

    3C273

    (0.19)

    1.22

    1.18

    no

    Started at 1.0 mm; Ar2 fit from (FWHM's only), peak fits are bad; Ar1 and Ar3 are reasonably good

    20260709s266-270

    3C273

    (0.44)

    1.16

    1.12

    no

    Started at 1.35 mm; Ar2 fit from (FWHM's only), peak fits are bad; Ar1 and Ar3 are good

    20260709s271-275

    3C273

    0.04

    out

    out

    no

    Started at 0.3 mm; s273 corrupted; even so, Ar2 has a confident fit, Ar1 and Ar3 out

    20260709s276-280

    3C273

    0.08

    out

    out

    no

    Started at 0.1 mm; Ar2 good, Ar1 and Ar3 out

    20260709s282-286

    3C273

    (0.23)

    1.17

    1.15

    no

    Started at 1.2 mm; Ar2 fit from (FWHM's only), marginal; Ar1 and Ar3 good

    20260709s287-291

    3C273

    (0.37)

    1.24

    1.20

    no

    Started at 1.4 mm; Ar2 fit from (FWHM's only), Ar1 and Ar3 good

    20260709s292-296

    3C273

    0.04

    out

    out

    no

    Started at 0.2 mm; Ar2 fit good; Ar1 and Ar3 out

    20260709s297-301

    3C273

    (0.42)

    1.18

    1.15

    no

    Started at 1.4 mm; Ar2 fit from (FWHM's only), Ar1 and Ar3 good

  • Selected focus fit plots:

Ar2 focus, scans 292-296 Ar1 focus, scans 287-291 Ar3 focus, scans 287-291

  • DAQ started at 20:55 (LT), window closed, telescope stopped, wind speed (max) ~10 m/s, bad KIDs (ar1, 2, 3): 10/5/8. The ladder above the cryostat and other possible sources of mechanical vibrations were checked: ok.

Ar2 noise traces, window closed Ar1 noise traces, window closed Ar3 noise traces, window closed

  • DAQ restarted at ~21:15, window open, bad KIDs (ar1, 2, 3): 28/6/20. Sampled spectra, El. ~70 deg.:

Ar2 noise traces, window open Ar1 noise traces, window open Ar3 noise traces, window open

Testing focus difference between the arrays: July 28, 2026

* First focus tests after the NIKA2 DAQ problem.

* Starting at 16h30 LT, under very poor weather conditions. Opacity ~ 1 (~ 0.8 towards the end of the session). However, not very unstable: +/- 5 to 7 Jy/beam peak-to-peak at 2 mm.

* Low wind (~ 2.5 m/s); ambient temperature ~ 20 C.

* 3C279: El. ~ 45 deg; 3C273: El. ~ 50 deg.

* Given the very high opacity, today's focus tests should be taken with a pinch of salt. Note also the large number of bad KIDs.

* Bad KIDs Ar1/Ar2/Ar3: 74/8/154

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260728s170-174

    3C273

    -0.06

    0.8

    0.74

    no

    Started at 0.8 mm; Ar2 fit from FWHM's only

    20260728s175-179

    3C273

    -0.12

    0.8

    0.8

    no

    Started at 0.8 mm; Ar2 fit from FWHM's only

    20260728s182-186

    3C273

    -0.06

    0.86

    --

    no

    Started at 0.8 mm; Ar2 fit from FWHM's only

    20260728s192-196

    3C273

    out

    1.18

    0.95

    no

    Started at 0.6 mm; Ar1 and Ar3 from gFit peak, but not nice

    20260728s197-201

    3C273

    -0.4

    1.15

    out

    no

    Started at 0.4 mm

    20260728s202-206

    3C273

    -0.52

    out

    out

    no

    Started at 0.4 mm

    20260728s209-213

    3C279

    -0.4

    0.7

    0.63

    no

    Started at 0.4 mm; Ar2 fit from FWHM's only

    20260728s214-218

    3C279

    -0.6

    0.72

    0.68

    no

    Started at 0.4mm; Ar1 and Ar2 fits from FWHM's only

* We try to recover more KIDs with a new tuning. Bad KIDs Ar1/Ar2/Ar3: 71/9/38.

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260728s227-231

    3C279

    -0.5

    0.78

    0.81

    no

    Started at 0.2 mm; Ar1 and Ar3 fits from FWHM's only

    20260728s232-236

    3C279

    -0.34

    0.85

    0.74

    no

    Started at 0.4 mm; Ar2 and Ar3 fits from FWHM's only

    20260728s237-241

    3C279

    -0.39

    0.92

    0.81

    no

    Started at 0.4 mm; all based on FWHM, but not good fits

    20260728s242-246

    3C279

    -0.2

    0.84

    0.77

    no

    Started at 0.6 mm; all based on FWHM; Ar3 fit bad

    20260728s247-251

    3C279

    -0.22

    0.8

    0.76

    no

    Started at 0.6 mm; Ar2 fit from FWHM's only

    20260728s252-256

    3C279

    -0.37

    0.9

    0.87

    no

    Started at 0.5 mm; all based on FWHM

    20260728s257-261

    3C279

    -0.34

    0.85

    0.7

    no

    Started at 0.5 mm; Ar2 fit from FWHM's only

* Focus offsets: Ar1-Ar2 = 1.16 mm, Ar3-Ar1 = -0.07 mm.

* Window open and low wind speed (~2.5 m/s), tau_225GHz ~ 1. Noise traces:

Ar1 noise traces, window open Ar2 noise traces, window open Ar3 noise traces, window open

Testing focus difference between the arrays: July 29, 2026

* Starting at 15 LT, under very poor weather conditions. Opacity ~ 1 most of the time, but ~ 0.6 towards the end of the session. Ambient temperature 19.9 C.

* Again: given the very high opacity, today's focus tests should be taken with a pinch of salt. Note also the large number of bad KIDs when NIKA2 window is open (tried retuning several times, but getting always similar results).

* Not able to get a calib_1scan on Mars (bad pointing and focus + low elevation) and similar situation at the end of the session on MWC349.

* Checking noise traces.

NIKA2 windows closed, vertex closed, mirrors pointing EMIR. Antenna at 70 deg in elevation. DAQ started at 15h16LT. Bad KIDS Ar1/Ar2/Ar3: 15/4/8.

Ar1 noise traces, window open Ar2 noise traces, window open Ar3 noise traces, window open

NIKA2 windows open, vertex open. Antenna at 70 deg in elevation. DAQ started at 16LT. Bad KIDS Ar1/Ar2/Ar3: 53/13/27.

Ar1 noise traces, window open Ar2 noise traces, window open Ar3 noise traces, window open

* Stopped for an hour waiting for the weather to improve and resumed observations at 18 LT. Bad KIDs Ar1/Ar2/Ar3: 56/8/30.

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260729s201-205

    3C279

    -0.34

    0.98

    0.91

    no

    Started at 0.67 mm; all based on FWHM

    20260729s206-210

    3C279

    -0.03

    1.07

    1.07

    no

    Started at 0.9 mm; Ar2 fit from FWHM's only

    20260729s211-215

    3C279

    out

    1.07

    1.01

    no

    Started at 1.1 mm

    20260729s221-225

    3C279

    -0.01

    1.06

    1

    no

    Started at 1.1 mm; Ar2 fit from FWHM's only

    20260729s226-230

    3C279

    -0.3

    0.89

    0.92

    no

    Started at 0.5 mm; Ar1 and Ar3 fits from FWHM's only

    20260729s231-235

    3C279

    -0.35

    0.85

    0.8

    no

    Started at 0.5 mm; Ar1 and Ar3 fits from FWHM's only

    20260729s236-240

    3C279

    -0.23

    out

    out

    no

    Started at 0.3 mm

    20260729s243-247

    3C279

    -0.06

    1

    0.95

    no

    Started at 0.9 mm; Ar2 fit from FWHM's only

* Focus offsets: Ar1-Ar2 = 1.16 mm, Ar3-Ar1 = -0.04 mm.

Testing focus difference between the arrays: July 30, 2026

* Starting with opacity ~ 0.8 and finishing with opacity ~ 0.5.

* Wind ~ 3 m/s; ambient temperature 19 C.

* Checking noise traces.

NIKA2 windows closed, vertex closed, mirrors pointing EMIR. Antenna at 70 deg in elevation. DAQ started at 15h08 LT. Bad KIDS Ar1/Ar2/Ar3: 24/6/9.

Ar1 noise traces, window open Ar2 noise traces, window open Ar3 noise traces, window open

NIKA2 windows open, vertex open. Antenna at 70 deg in elevation. DAQ started at 15h30 LT. Bad KIDS Ar1/Ar2/Ar3: 34/10/20.

Ar1 noise traces, window open Ar2 noise traces, window open Ar3 noise traces, window open

* Two calib_1scan on Mars (20260730s202 and 20260730s203), under pretty bad conditions; with focus correction from Ar1 and pointing correction from Ar2.

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260730s207-211

    3C273

    -0.40

    0.98

    0.74

    no

    Started at 0.5 mm; Ar2 fit from FWHM's only

    20260730s212-216

    3C273

    -0.50

    out

    0.45

    no

    Started at 0.0 mm; Ar3 is missing a scan

    20260730s217-221

    3C273

    -0.58

    out

    out

    no

    Started at -0.3 mm

    20260730s222-226

    3C273

    -0.46

    1.01

    0.96

    no

    Started at 0.5 mm; Ar2 fit from FWHM's only

    20260730s227-231

    3C273

    out

    0.78

    0.71

    no

    Started at 0.9 mm

    20260730s246-250

    3C279

    out

    0.80

    0.75

    no

    Started at 1.0 mm

    20260730s252-256

    3C279

    -0.39

    out

    out

    no

    Started at -0.6 mm

* Finished the slot with a few test scans for the NIKA2 high-frequency noise analysis, but only for the 60”/sec version, but only checking the vertex status (open/closed). Test scan range: 20260730s257 and 20260730s265.

* Focus offsets: Ar1-Ar2 = 1.28 mm, Ar3-Ar1 = -0.06 mm.

Testing focus difference between the arrays: July 31, 2026

* Opacity at the beginning: ~0.7; increasing up to ~1 at the end of the shift along with atmosphere instabilities. Peak-to-peak variations of the timelines > 10 Jy/beam (2 mm).

* Max. wind speed between 6 and 9 m/s; ambient temperature up to 21C. Enhanced 2mm-beam shape: 20.2" x 20.9" from a pointing scan after the first best focus on Ar2.

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260731s190-194

    3C273

    (-0.16)

    0.71

    0.68

    no

    Started at 1 mm; Ar2 marginal (Ar2 fit from FWHM only); Ar1 and 3 good

    20260731s195-199

    3C273

    -0.68

    (0.33)

    (0.25)

    no

    Started at -0.3 mm; Ar2 good; Ar1 and Ar3 marginal (fit values from FWHM only)

    20260731s201-205

    3C273

    (-0.22)

    0.74

    0.65

    no

    Started at 0.8 mm; Ar2 marginal (Ar2 fit from FWHM only); Ar1 and 3 good

    20260731s206-210

    3C273

    -0.72

    out

    out

    no

    Started at -0.1 mm; Ar2 good; Ar1 and Ar3 bad

    20260731s212-216

    3C273

    -0.61

    out

    out

    no

    Started at -0.6 mm; Ar2 good; Ar1 and Ar3 bad

    20260731s217-221

    3C273

    (-0.18)

    0.73

    0.68

    no

    Started at 0.8 mm; Ar2 marginal (Ar2 fit from FWHM only); Ar1 and Ar3 good

  • Focus offsets: Ar1-Ar2 = 1.38 mm, Ar3-Ar1 = -0.06 mm.

  • Selected focus fit plots:

Ar2 focus, scans 195-199 Ar1 focus, scans 190-194 Ar3 focus, scans 190-194

Ar2 focus, scans 212-216 Ar1 focus, scans 217-221 Ar3 focus, scans 217-221

* After the last focus correction, a series of scans on Arp220 for testing high-frequency noise was launched: (i) on-sky (opacity/instabilities increased substantially in the middle): scans 20260731s231-233 (120 arcsec/s), s234-236 (60 arcsec/s) and (ii) window closed: scans s237-239 (120 arcsec/s), s240-242 (60 arcsec/s). Scans with vertex closed + window open omitted by mistake (AB). Scans s243-248 should not be used.

* Checking noise traces:

NIKA2 window closed, vertex close, mirrors pointing EMIR. Antenna at 70 deg in elevation. DAQ started at 15:05 LT. Bad KIDS Ar1/Ar2/Ar3: 13/6/11.

Ar2 noise traces, window open Ar1 noise traces, window open Ar3 noise traces, window open

NIKA2 window open, vertex open. Antenna at 70 deg in elevation. DAQ re-started at ~15:50 LT. Bad KIDS Ar1/Ar2/Ar3: 49/9/25.

Ar2 noise traces, window open Ar1 noise traces, window open Ar3 noise traces, window open

Testing focus difference between the arrays: August 4, 2026

  • Test was delayed due to problems with EMIR and FTS. Prioritize solving them to make sure that all projects of that week run without problems. Started with NIKA2 test time (T21-26) at 19:00 LT.
  • NIKA2 tuning with bad KIDs 77/8/34 (Ar1/Ar2/Ar3). Traces look normal in all three arrays. No prominent bumps (just a broad bump around 1 Hz when NIKA2 window is closed, similar to the one seen in the last test). Opacity at the beginning: ~0.6; increasing up to ~0.8 at the end of the shift along with atmosphere instabilities. Peak-to-peak variations of the timelines cover a wide range, about 2-10 Jy/beam (2 mm). Max. wind speed between 4 and 6 m/s.
  • ql_new_run92 directory folder imbfitsDir symbolic link changed to the new "August" directory (/mnt/data/NIKAIMBFITS/2026/08) to point to the place with the latest data.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260804s171-175

    3C273

    (-0.02)

    1.07

    1.00

    no

    Started at 1.0 mm; Ar2 marginal (Ar2 fit from FWHM only); Ar1 and 3 good

    20260804s176-180

    3C273

    -0.19

    out

    out

    no

    Started at -0.6 mm; Ar2 good; Ar1 and Ar3 out of bounds

    20260804s181-185

    3C273

    (0.26)

    0.99

    0.98

    no

    Started at 1.2 mm; Ar2 marginal (Ar2 fit from FWHM only); Ar1 and 3 good

    20260804s187-191

    3C279

    -0.43

    out

    out

    no

    Started at -0.4 mm; Ar2 good; Ar1 and Ar3 out of bounds

    20260804s187-191

    3C279

    (-0.19)

    0.98

    0.87

    no

    Started at 1.4 mm; Ar2 marginal (Ar2 fit from FWHM only); Ar1 and 3 good

  • Focus offsets: Ar1-Ar2 = 1.30 mm, Ar3-Ar1 = -0.06 mm.

  • Selected focus fit plots:

Ar2 focus, scans 187-191 Ar1 focus, scans 192-196 Ar3 focus, scans 192-196

NIKA2 test time: August 5, 2026

  • NIKA2 tuning with bad KIDs 78/15/34 (Ar1/Ar2/Ar3). Traces look normal in all three arrays, no prominent bumps. Opacity at the beginning: ~0.9; stayed high (>0.7) throughout the shift along with atmosphere instabilities. Peak-to-peak variations of the timelines cover a wide range, about 2-10 Jy/beam (2 mm). Max. wind speed between 4 and 9 m/s.

  • Selected noise traces plots : windows open, vertex open.

Ar1 noise traces, window open, vertex open Ar2 noise traces, window open, vertex open Ar3 noise traces, window open, vertex open

  • High opacity but beam shape was less extended than expected: 18.0" x 21.0 for Ar2 " and 14.1" x 15.7" for Ar1 from a few pointing scans after the optimizing focus on Ar2 and Ar1, respectively.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260805s158-162

    3C273

    -0.50

    out

    out

    no

    Started at -0.5 mm; Ar2 good; Ar1 and Ar3 out of bounds

    20260805s163-167

    3C273

    (0.01)

    0.97

    0.92

    no

    Started at 1.0 mm; Ar2 marginal (Ar2 fit from FWHM only); Ar1 and 3 good

    20260805s180-184

    3C279

    -0.32

    out

    out

    no

    Started at -0.7 mm; Ar2 good; Ar1 and Ar3 out of bounds

    20260805s190-194

    3C279

    out

    0.75

    0.61

    no

    Started at 0.9 mm; Ar2 out of bounds; Ar1 and 3 good

    20260805s195-199

    3C279

    -0.43

    out

    out

    no

    Started at -0.4 mm; Ar2 good; Ar1 and Ar3 out of bounds

    20260804s200-204

    3C279

    (-0.54)

    0.75

    0.67

    no

    Started at 0.6 mm; Ar2 marginal (Ar2 fit from FWHM only); Ar1 and 3 good

  • Focus offsets: Ar1-Ar2 = 1.24 mm, Ar3-Ar1 = -0.09 mm.

  • Selected focus fit plots:

Ar2 focus, scans 195-199 Ar1 focus, scans 200-204 Ar3 focus, scans 200-204

  • For the last part of the slot, the opacity stayed high (>0.7) but the stability was acceptable (4-5 Jy/beam), so decided to take some test scans for the NIKA2 high-frequency noise analysis. First we did the 60"/sec version for all vertex/window open/close combinations, scan range 20260805s210-218. Then, with the closed window version tuning of box "I" was lost so repeat the tuning with bad KIDs 124/17/35 (Ar1/2/3, increased due to bad weather?). Then I continued with the 120"/sec version for all vertex/window open/close combinations, scan range 20260805s223-231.

NIKA2 test time: August 6, 2026

  • NIKA2 tuning with bad KIDs 58/12/28 (Ar1/Ar2/Ar3). Traces look normal in all three arrays, no prominent bumps (except the known broad bump for Ar1 when window and ventex are closed, see above). Opacity at the beginning: ~0.65; decreased during the session down to ~0.45 and atmosphere instabilities improved towards the end. Peak-to-peak variations of the timelines about 2-7 Jy/beam (2 mm), with a few extreme variations up to +/- 15 Jy/beam in the middle of the session. Max. wind speed between 3 and 8 m/s.
  • From 16:15 LT to 17:30 LT strong sky instabilities (about 10-30 Jy/beam).
  • Checking noise traces:

NIKA2 window closed, vertex closed, mirrors pointing EMIR. Antenna at 35 deg in elevation. DAQ started at 15:06 LT. Bad KIDS Ar1/Ar2/Ar3: 19/6/9.

Ar2 noise traces, window open Ar1 noise traces, window open Ar3 noise traces, window open

NIKA2 window open, vertex open. Antenna at 35 deg in elevation. DAQ re-started at ~15:40 LT. Bad KIDS Ar1/Ar2/Ar3: 59/9/34.

Ar2 noise traces, window open Ar1 noise traces, window open Ar3 noise traces, window open

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260806s159-163

    3C273

    -0.38

    out

    out

    no

    Started at -0.7 mm; Ar2 good; Ar1 and Ar3 out of bounds

    20260806s164-168

    3C273

    out

    0.96

    0.87

    no

    Started at 1.3 mm; Ar2 out of bounds; Ar1 and 3 good

    20260806s174-178

    3C273

    -0.23

    out

    out

    no

    Started at -0.4 mm; Ar2 good; Ar1 and Ar3 out of bounds

    20260806s179-183

    3C273

    (0.09)

    0.94

    0.91

    no

    Started at 1.0 mm; Ar2 out of bounds; Ar1 and 3 good

    20260806s204-208

    3C279

    -0.67

    out

    out

    no

    Started at -0.5 mm; Ar2 good; Ar1 and Ar3 out of bounds

    20260806s209-213

    3C279

    (-0.13)

    0.81

    0.73

    no

    Started at 1.0 mm; Ar2 out of bounds; Ar1 and 3 good

  • Focus offsets: Ar1-Ar2 = 1.33 mm, Ar3-Ar1 = -0.07 mm.

  • Opacity decreased (<0.5) and the stability is still acceptable (4-5 Jy/beam), so decided to take some test scans again for the NIKA2 high-frequency noise analysis. But we just had time to do the 60"/sec version for all vertex/window open/close combinations, scan range 20260806s193-201.

NIKA2 test time slots: August 7-10, 2026

  • Weather conditions too bad to do any measurements during these T21-26 slots.

NIKA2 focus test: August 28, 2026

  • Starting NIKA2 shift with NIKA2 (thanks to a chance within the heterodyne pool week) at 18:05 LT. T_MC ~186 mK with fluctuations (~1.5 mK) and P101 ~1440 mbar with some instabilities in the last hours (the cold amplifier of Ar3 was switched in the morning). According to Dave, it's okay for focus tests.
  • Opacity at the beginning: ~0.2; peak-to-peak variations of the timelines between 3 and ~10 Jy/beam (2 mm) along the session. Max. wind speed between 2 and 6 m/s. Starting with 3C279 at El. ~40 deg. Then, 3C273. Fantastic tracking. PIIC-QL data are still being at ql_new_run92 directory of t22 account.

  • Noise spectra:

NIKA2 window closed, vertex closed, mirrors pointing EMIR. DAQ started at 18:07 LT. NIKA2 tuning with bad KIDs, window closed: 13/1000, 6/574, 10/749 (Ar1, Ar2, Ar3). Traces look fine for arrays 2 and 3. Some correlated noise for array 1:

Ar2 noise traces, window closed Ar1 noise traces, window closed Ar3 noise traces, window closed

NIKA2 tuning on-sky at 18:25 LT with bad KIDs 16, 6, 17 (Ar1, Ar2, Ar3), El. = 70 deg. Traces recorded after the focus tests (~19:50 LT), blank sky, El. = 70 deg.:

Ar2 noise traces, window open Ar1 noise traces, window open Ar3 noise traces, window open

  • Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260828s72-76

    3C279

    (-0.22)

    0.67

    0.6

    no

    Started at 1.0 mm; Ar2 marginal (fit from FWHM only); Ar1 and 3 resonably good

    20260828s77-81

    3C279

    -0.54

    out

    out

    no

    Started at -0.2 mm; Ar2 good; Ar1 and Ar3 bad

    20260828s83-87

    3C273

    (-0.47)

    0.7

    0.63

    no

    Started at 0.9 mm; Ar2 quite marginal (fit from FWHM only); Ar1 and Ar3 good

    20260828s88-92

    3C273

    -0.45

    out

    out

    no

    Started at -0.3 mm; Ar2 good; Ar1 and Ar3 bad

    20260828s93-97

    3C273

    (-0.14)

    0.9

    0.85

    no

    Started at 1.0 mm; Ar2 marginal (fit from FWHM only); Ar1 and Ar3 good (not so Ar1 FWHM fitting)

    20260828s98-102

    3C273

    -0.47

    out

    out

    no

    Started at -0.2 mm; Ar2 good; Ar1 and Ar3 bad

  • Focus offsets: Ar1-Ar2 = 1.26 mm, Ar3-Ar1 = -0.06 mm.

NIKA2 focus test: August 29, 2026

  • Today Mixing Chamber temperature is again T_MC ~186 mK and P101 ~1439 mbar. We proceed with focus tests.
  • Opacity all along the shift: ~0.4; peak-to-peak variations at 2 mm: ~ 5 Jy/beam. Max. wind speed around 3 m/s.
  • Observing 3C279 from El. ~40 deg to ~27 deg.
  • DAQ started at 18h10LT. NIKA2 tuning at 70 deg in elevation; bad KIDs (NIKA2 window and vertex open): 38/1000, 17/574, 15/749 (Ar1, Ar2, Ar3). Several attempts to improve the number of good KIDs, but getting always very similar numbers. Traces look fine.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260829s155-159

    3C279

    (-0.55)

    0.5

    0.45

    no

    Started at 0.4 mm; Ar2 marginal (fit from FWHM only)

    20260829s160-164

    3C279

    (-0.63)

    0.87

    0.8

    no

    Started at 0.6 mm; Ar2 marginal (fit from FWHM only)

    20260829s165-169

    3C279

    -0.6

    (0.76)

    (0.67)

    no

    Started at 0.0 mm; Ar2 good; (Ar1 and Ar3 gFit peak only)

    20260829s170-174

    3C279

    -0.43

    0.7

    out

    no

    Started at 0.1 mm; Ar2 good

    20260829s175-179

    3C279

    -0.46

    0.55

    0.43

    no

    Started at 0.2 mm; Ar2 good and reasonable Ar1 & Ar3 (except for FWHM fitting)

    20260829s181-185

    3C279

    (-0.7)

    out

    out

    no

    Started at 0.3 mm; Ar2 marginal (fit from FWHM only)

  • Focus offsets: Ar1-Ar2 = 1.16 mm, Ar3-Ar1 = -0.08 mm.

NIKA2 focus test: August 30, 2026

  • Today Mixing Chamber temperature is T_MC ~187 mK and P101 ~1455 mbar. We proceed with focus tests.
  • Opacity all along the shift: ~0.4; peak-to-peak variations at 2 mm: ~ 5 Jy/beam. Max. wind speed around 3 m/s.
  • Observing 3C273 from El. ~40 deg to ~27 deg.
  • DAQ started at 18h05LT. NIKA2 tuning at 63 deg in elevation; bad KIDs (NIKA2 window and vertex open): 27/1000, 9/574, 13/749 (Ar1, Ar2, Ar3). Traces look fine with somewhat more structure for Ar1.

    Focus sequences

    Scan nr

    Target

    Ar2

    Ar1

    Ar3

    Polarized?

    Notes

    20260829s155-159

    3C279

    (-0.55)

    0.5

    0.45

    no

    Started at 0.4 mm; Ar2 marginal (fit from FWHM only)

    20260829s160-164

    3C279

    (-0.63)

    0.87

    0.8

    no

    Started at 0.6 mm; Ar2 marginal (fit from FWHM only)

    20260829s165-169

    3C279

    -0.6

    (0.76)

    (0.67)

    no

    Started at 0.0 mm; Ar2 good; (Ar1 and Ar3 gFit peak only)

    20260829s170-174

    3C279

    -0.43

    0.7

    out

    no

    Started at 0.1 mm; Ar2 good

    20260829s175-179

    3C279

    -0.46

    0.55

    0.43

    no

    Started at 0.2 mm; Ar2 good and reasonable Ar1 & Ar3 (except for FWHM fitting)

    20260829s181-185

    3C279

    (-0.7)

    out

    out

    no

    Started at 0.3 mm; Ar2 marginal (fit from FWHM only)

  • Focus offsets: Ar1-Ar2 = 1.16 mm, Ar3-Ar1 = -0.08 mm.

Summary of focus offset tests (mean values) - Run 80

Please update this table after a new session and keep it at the bottom of the page. FWHM-only individual focus corrections were not taken into account:

  • Session dates

    Ar1-Ar2 [mm]

    Ar3-Ar1 [mm]

    Warm-up starts (full/partial)

    Cool-down ends

    24/3 - 31/3/2026 (*)

    1.08

    -0.04

    03/3 (full)

    18/3

    25/3

    1.00

    -0.05

    25/4

    1.15

    -0.05

    09/4 (full)

    24/4

    19/5

    1.01

    -0.03

    20/5

    1.15

    -0.02

    21/5

    1.17

    -0.05

    05/6

    1.13

    -0.05

    22/5 (partial)

    26/5

    09/6

    1.17

    -0.05

    08/7

    1.27

    -0.03

    12/6 (full)

    02/7

    09/7

    1.14

    -0.04

    28/7 (Considering FWHM-only individual focus corrections, otherwise no results)

    1.16

    -0.07

    16/7 (partial)

    23/7

    29/7 (Considering FWHM-only individual focus corrections, otherwise no results)

    1.16

    -0.04

    30/7

    1.28

    -0.06

    31/7

    1.38

    -0.06

    04/8

    1.30

    -0.06

    05/8

    1.24

    -0.09

    06/8

    1.33

    -0.07

    28/8

    1.26

    -0.06

    17/8 (partial)

    23/8

    29/8

    1.16

    -0.08

    (*) Re-commissioning week.

Run80processing (last edited 2026-08-30 17:59:13 by imyserlis)