[[Nika2Run74|Back to the NIKA2 Run 74 main page]] <<BR>>
Line 3: Line 2:
<<TableOfContents(3)>> = PIIC processing of run 74 beam maps (taken on 2025/07/13) =
Line 5: Line 4:
= NIKA2 Re-Commissioning (3rd. attempt) = Three beam maps were taken on 2025/07/13, i.e. scans
|| Scan || Focus || Notes ||
|| 20250713s45 || Ar2 || ||
|| 20250713s47 || Ar1 || weird behavious in the IDL reduction by NP on 2025/07/15 ||
|| 20250713s78 || Ar1 || although it's meant to be used for Ar3||
Line 7: Line 10:
NIKA2 run 74, Cryo run 86

== Infos about the PIIC DAFs for the PIIC monitor ==

According to the results obtained from processing data of June 2025 NIKA2 re-commissioning given [[https://publicwiki.iram.es/Run73processing|here]], DAFs RPP scheme used during run 73 is kept. Therefore, two different sets of DAFs for Ar1+3 and for Ar2 are used. In practice:

 * Ar2
  * open a terminal, go to the QL directory
  * gagpiic
  * export MOPSIC_DAFS=/local/users/flexible/reduce/dafs_bck/dafs_local_tmp_run73_ar2
  * start the Ar2 monitor (pf)
  * repeat in another terminal for the Ar2 monitor(m)

 * Ar1 and Ar3
  * open a new terminal, go to the QL directory
  * gagpiic
  * echo $MOPSIC_DAFS -> check that it says /sw/gildas/mopsic/dafs
  * if not, then set it to that directory
  * proceed normally with the Ar1 and Ar3 monitors

== July 12th, 2025 ==
On 2025/07/17 SB processed the three beam maps using PIIC. Below here I copy the usual FOV plots, that show the quality of the beam maps. They are self-explanatory (cfr also the previous re-commissioning runs for more information). It is worth to point out few features, though:
 * also in this re-commissioning session, the Ar3 beam maps are bad. My feeling is that the main culprit is the focus offset of Ar3 with respect to Ar1 and Ar2.
 * there is a focus difference of ~0.3 mm between Ar2 and Ar1, a difference of ~0.3 mm between Ar1 and Ar3, and therefore a difference of ~0.6 mm between Ar2 and Ar3. These values are preliminary and come from the quick focus analysis carried out during the observing session. Note that during the first re-commissioning (run 72), Ar1 and Ar3 seemd to have a similar focus offset, but things changed after re-opnening. The idea is that this is not a real hardware change, but rather due to the fact that in run 72 the Box C was missing. In my opinion this is not so obvious, though.
 * the consequences of these focus offsets between the three arrays are that: focusing on Ar2, Ar3 is completely out of focus and not usable; fcusing on Ar1, Ar3 is still out of focus (but less dramatically) and only marginally usable.
 * there have been issues with focusing at 1.2 mm

PIIC processing of run 74 beam maps (taken on 2025/07/13)

Three beam maps were taken on 2025/07/13, i.e. scans

Scan

Focus

Notes

20250713s45

Ar2

20250713s47

Ar1

weird behavious in the IDL reduction by NP on 2025/07/15

20250713s78

Ar1

although it's meant to be used for Ar3

On 2025/07/17 SB processed the three beam maps using PIIC. Below here I copy the usual FOV plots, that show the quality of the beam maps. They are self-explanatory (cfr also the previous re-commissioning runs for more information). It is worth to point out few features, though:

  • also in this re-commissioning session, the Ar3 beam maps are bad. My feeling is that the main culprit is the focus offset of Ar3 with respect to Ar1 and Ar2.
  • there is a focus difference of ~0.3 mm between Ar2 and Ar1, a difference of ~0.3 mm between Ar1 and Ar3, and therefore a difference of ~0.6 mm between Ar2 and Ar3. These values are preliminary and come from the quick focus analysis carried out during the observing session. Note that during the first re-commissioning (run 72), Ar1 and Ar3 seemd to have a similar focus offset, but things changed after re-opnening. The idea is that this is not a real hardware change, but rather due to the fact that in run 72 the Box C was missing. In my opinion this is not so obvious, though.
  • the consequences of these focus offsets between the three arrays are that: focusing on Ar2, Ar3 is completely out of focus and not usable; fcusing on Ar1, Ar3 is still out of focus (but less dramatically) and only marginally usable.
  • there have been issues with focusing at 1.2 mm