Differences between revisions 3 and 4
Revision 3 as of 2015-10-13 20:55:32
Size: 1279
Comment:
Revision 4 as of 2015-10-13 20:56:36
Size: 1401
Comment:
Deletions are marked like this. Additions are marked like this.
Line 29: Line 29:
|| 93-97 || 20h50 || Uranus || focuslissold || 112 || 37 || 0,0,0.1 || 0.4 || ||

NIKA October 13th, 2015 / S1

Back to list of day to day logbook of observations

2015-10-13


Following not updated

.Cryostat Temperature: 170mK cooling down slowly

  • Arrays status tonight: full 2mm array - 1-3 Hz noise; 2 feed lines on 1mm array 3-5Hz noise

Modulation frequency: 10kHz 1mm, 5kHz 2mm

Opacity is measured with the new taumeter at 225 GHz

Nasmyth offsets : 0, 0

Set Focus : we start at -2mm (not at all optimised, first task is try to improve on this!)

  • Quick description of the session: Test the Pako sequences and data flows.


Data Repository: /home/nika2/NIKA/Data/run13_X/scan24_X

Scan

UT

Source

Command

Az

El

Pointing X, Y, Focus

Tau225

Comment

88-89

20h29

Uranus

Track

109

34

0,0,0.1

0.4

90

20h41

Uranus

Pointcross

112

37

0,0,0.1

0.4

set pointing -16.6 3.0

92

20h48

Uranus

Pointcross

112

37

0,0,0.1

0.4

set pointing -18 2.7 : check !, fwhm=13.8, 19.8 arcsec

93-97

20h50

Uranus

focuslissold

112

37

0,0,0.1

0.4