Line 25: Line 25:
Acquisition = 39 Hz Acquisition = 39.7 Hz
Line 29: Line 29:
Values in brackets [] are not updated. Remark after few scans: [[https://tapas.iram.es/tapas/ | TAPAS]] is working now, we see the scans, but we continue the manual log just in case.
Line 32: Line 32:
|| 1-3 || 00h46 || Uranus || Track off -200 -200 || 208 || 54 || 0,0,-2.4 || 0.5 || Tuning ||
|| 4 || 00h46 || Uranus || Cross || 208 || 54 || 0,0,-2.4 || 0.5 || ||
|| 1-3 || 00h46 || Uranus || Track off -200 -200 || 208 || 54 || 0,0,-2.4 || 0.2 || Tuning. We started a bit late, the time that ice melts and sky clears ! ||
|| 4 || 00h50 || Uranus || cross || 208 || 54 || 0,0,-2.4 || 0.2 || ||
|| 5 || 00h56 || Uranus || cross || 213 || 53 || 0,0,-2.4 || 0.1 || Problem processing the scan ||
|| 6 || 01h00 || Uranus || cross || 213 || 53 || 0,0,-2.4 || 0.1 || ||
|| 7 || 01h03 || Uranus || cross || 213 || 53 || -2.5,6.4,-2.4 || 0.1 || set pointing -2.5 6.4 ||
|| 8 || 01h08 || Uranus || focusp || 213 || 53 || -2.5,6.4,-2.4 || 0.1 || ||
|| 9 || 01h03 || Uranus || cross || 213 || 53 || -2.5,6.4,-2.0 || 0.1 || set focus -2.0 ||
|| 10 || 01h08 || Uranus || focusp || 213 || 53 || 3.5,-3.8,-2.0 || 0.1 || Jumps in data, bad for processing ||
|| 11 || 01h17 || Uranus || focusp || 220 || 51 || 3.5,-3.8,-2.0 || 0.1 || ||
|| 12 || 01h25 || Uranus || otfgeom_25 || 220 || 49 || 3.5,-3.8,-2.0 || 0.1 || surely defocussed, but useful to debug holes with dataprocessing||
|| 13 || 01h38 || Uranus || focusp || 225 || 48 || 3.5,-3.8,-2.0 || 0.1 || ||
|| 14-18 || 01h45 || Uranus || focusliss || 225 || 48 || 3.5,-3.8,-2.0 || 0.1 || ||
|| 19-23 || 01h52 || Uranus || focusliss || 230 || 48 || 3.5,-3.8,-1.4 || 0.1 || ||
|| 24-28 || 01h55 || Uranus || focusliss || 230 || 48 || 3.5,-3.8,-0.6 || 0.1 || we were visibly completely out of focus in preceeding scans ||
|| 29 || 02h10 || Uranus || cross || 235 || 41 || 3.5,-3.8,-0.6 || 0.2 || ||
|| 30 || 02h20 || Uranus || cross || 235 || 41 || -2.3,6.2,-0.6 || 0.2 || ||
|| 31 || 02h25 || Uranus || focusp || 240 || 38 || -2.3,6.2,-0.6 || 0.2 || say focus -0.77 ||
|| 32 || 02h28 || Uranus || otfgeom_25 || 240 || 38 || -2.3,6.2,-0.6 || 0.2 || ||
|| 33 || 02h49 || Uranus || otf3x3 || 240 || 38 || -2.3,6.2,-0.6 || 0.2 || HWP in reference position ||
|| 34 || 02h54 || Uranus || otf3x3 || 240 || 38 || -2.3,6.2,-0.6 || 0.2 || HWP in reference position ||
|| 35 || 03h01 || Uranus || otf3x3 || 240 || 38 || -2.3,6.2,-0.6 || 0.2 || HWP + 7 steps anti-clockwise (facing cryostat) ||
|| 36 || 03h07 || Uranus || otf3x3 || 240 || 38 || -2.3,6.2,-0.6 || 0.2 || HWP + 7 steps anti-clockwise (facing cryostat) ||

NIKA October 10th, 2014 / S4

Back to list of day to day logbook of observations

2014-10-10


Opacity is measured with the new taumeter at 225 GHz

Nasmyth offsets : -19, 5.8

Set pointing : 0, 0

Set Focus : -2.4 mm

  • Quick description of the session: measure polarization of quasars at various elevations and planets to test our system and calibrate


Polarizer on, HWP on but not turning at session start

Data Repository: Raw_X9

Acquisition = 39.7 Hz

Observing account: t21

Remark after few scans: TAPAS is working now, we see the scans, but we continue the manual log just in case.

Scan

UT

Source

Command

Az

El

Pointing X, Y, Focus

Tau225

Comment

1-3

00h46

Uranus

Track off -200 -200

208

54

0,0,-2.4

0.2

Tuning. We started a bit late, the time that ice melts and sky clears !

4

00h50

Uranus

cross

208

54

0,0,-2.4

0.2

5

00h56

Uranus

cross

213

53

0,0,-2.4

0.1

Problem processing the scan

6

01h00

Uranus

cross

213

53

0,0,-2.4

0.1

7

01h03

Uranus

cross

213

53

-2.5,6.4,-2.4

0.1

set pointing -2.5 6.4

8

01h08

Uranus

focusp

213

53

-2.5,6.4,-2.4

0.1

9

01h03

Uranus

cross

213

53

-2.5,6.4,-2.0

0.1

set focus -2.0

10

01h08

Uranus

focusp

213

53

3.5,-3.8,-2.0

0.1

Jumps in data, bad for processing

11

01h17

Uranus

focusp

220

51

3.5,-3.8,-2.0

0.1

12

01h25

Uranus

otfgeom_25

220

49

3.5,-3.8,-2.0

0.1

surely defocussed, but useful to debug holes with dataprocessing

13

01h38

Uranus

focusp

225

48

3.5,-3.8,-2.0

0.1

14-18

01h45

Uranus

focusliss

225

48

3.5,-3.8,-2.0

0.1

19-23

01h52

Uranus

focusliss

230

48

3.5,-3.8,-1.4

0.1

24-28

01h55

Uranus

focusliss

230

48

3.5,-3.8,-0.6

0.1

we were visibly completely out of focus in preceeding scans

29

02h10

Uranus

cross

235

41

3.5,-3.8,-0.6

0.2

30

02h20

Uranus

cross

235

41

-2.3,6.2,-0.6

0.2

31

02h25

Uranus

focusp

240

38

-2.3,6.2,-0.6

0.2

say focus -0.77

32

02h28

Uranus

otfgeom_25

240

38

-2.3,6.2,-0.6

0.2

33

02h49

Uranus

otf3x3

240

38

-2.3,6.2,-0.6

0.2

HWP in reference position

34

02h54

Uranus

otf3x3

240

38

-2.3,6.2,-0.6

0.2

HWP in reference position

35

03h01

Uranus

otf3x3

240

38

-2.3,6.2,-0.6

0.2

HWP + 7 steps anti-clockwise (facing cryostat)

36

03h07

Uranus

otf3x3

240

38

-2.3,6.2,-0.6

0.2

HWP + 7 steps anti-clockwise (facing cryostat)

NK2014_Oct12 (last edited 2014-10-14 01:02:08 by NikaBolometer)