Differences between revisions 1 and 2
Revision 1 as of 2012-12-13 09:31:42
Size: 525
Comment:
Revision 2 as of 2012-12-13 09:35:59
Size: 549
Comment:
Deletions are marked like this. Additions are marked like this.
Line 10: Line 10:
  as the IMBFits files of 1mm & 2mm were created ate the same time it shows that
 
this was not a problem of the IMBFits creation but of the availability of the NIKA data
  as the IMBFits files of 1mm & 2mm were created at the same time indicates that the creation of the IMBFits did not take so long but that the NIKA data were first available after such time delay

The synchronization problems were of different kind

- data for some subscans were not available, i.e. the IMBFits tables are either empty or have wrong data

- data after the start of a scan are first set (i.e. not 0) then 0

- data before the subscan end are 0

- the IMBFits were created 5 to 10 minutes after the observation was finished;

  • as the IMBFits files of 1mm & 2mm were created at the same time indicates that the creation of the IMBFits did not take so long but that the NIKA data were first available after such time delay