Differences between revisions 3 and 42 (spanning 39 versions)
Revision 3 as of 2007-05-17 16:32:30
Size: 391
Editor: lt-sl
Comment:
Revision 42 as of 2009-04-16 08:26:47
Size: 3008
Editor: localhost
Comment: converted to 1.6 markup
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
Mambo Bolometer at IRAM-30m <<Anchor(beginOfPage)>>

'''THIS PAGE IS OUTDATED !!! (CK, 15.11.08)'''

Mambo Bolometers at IRAM-30m
Line 4: Line 8:
[[TableOfContents]]
<<
TableOfContents>>
Line 9: Line 14:
The Mambo-1 and Mambo-2 bolometers have been developed at the [http://www.mpifr-bonn.mpg.de/div/bolometer/ Max-Planck-Institut fur Radiostronomie] in Bonn by the group of Ernst Kreysa. The Mambo-1 and Mambo-2 bolometers have been developed at the [[http://www.mpifr-bonn.mpg.de/div/bolometer/|Max-Planck-Institut fur Radiostronomie]] in Bonn by the group of Ernst Kreysa: ''MAMBO's 37 channel array has been successfully used by many observers since the end of 1998. Winter 2001/2002 was the first season of the new MAMBO-2 version with 117 pixels. The 37 channel MAMBO is used at the 30 m telescope as a backup system now. Both systems work at 1.2 mm wavelength and have a He-3 fridge to operate the bolometers at a temperature of 300 mK.''
Line 11: Line 16:
[[#beginOfPage|Top]]
Line 14: Line 20:
=== He-Refilling ===
Line 15: Line 22:
When in use, Mambo1 or Mambo2 are currently refilled with He4 every 48 hours. This procedure takes about 4-5 hours. It can be used for heterodyne observations.


=== OnOff pixel ===
   * Mambo1: pixel 1 is the most sensitive.
   * Mambo2: pixel 20 is the most sensitive.


=== Dead/Noisy Pixels ===


=== Instabilities ===
  * Acceleration problem:
  * '''Gradient noise''': about 6 % of scans are affected (stat. between 20.03.2007 and 30.03.2007)


[[#beginOfPage|Top]]
Line 17: Line 41:
The bolometers have two basic modes of observations:
  * '''On-Off''': flux measurement with a single pixel on a point-like source, using the wobbler switching.
  * '''Mapping''': On-the-fly map using the wobbler switching. By default the on-the-fly scanning is along the azimuth direction together with the wobbler switching. It is now possible to '''rotate the wobbler''' with the scanning direction to get rotated map. The rotated angle is currently in the range [-60,60] degrees.
Line 18: Line 45:
[[#beginOfPage|Top]]
Line 20: Line 48:
The data from the bolometer observations are recorded in IMBfits format. The data can be reduced using the Mopsic program (<<MailTo(zylka@iram.fr)>>) which is part of the GILDAS package.
Line 21: Line 50:
[[#beginOfPage|Top]]
Line 22: Line 52:
== Technical Issues ==

  * MinutesMeeting
  * TechnicalTests
  * [[PointingMonitoring|Pointing]]
  * [[NoiseStat|Noise statistics]]: noise measurements from observations on about 9000 scans. We estimate the noise statistics and the detection probability.

[[#beginOfPage|Top]]
Line 24: Line 62:
Pool Manager: S. Leon (<<MailTo(leon@iram.es)>>) <<BR>>
Bolometer Expert: A. Sievers (<<MailTo(sievers@iram.es)>>) <<BR>>
Mambo/Abba expertise: G. Siringo (<<MailTo(gsiringo@mpifr-bonn.mpg.de)>>) <<BR>>
Mopsic development: R. Zylka (<<MailTo(zylka@iram.fr)>>) <<BR>>
Line 25: Line 67:
[[#beginOfPage|Top]]
== Useful Links ==
Line 26: Line 70:
== Useful Links ==    * [[http://www.iram.es/IRAMES/mainWiki/PoolObserving|Mambo pool]] at the IRAM-30m.
   * [[http://www.iram.es/IRAMES/obstime/time_estimator.html|Time estimator]] for the bolometers and heterodyne receivers.
   * AbsorberTests to find the different tests done with absorbers and the He-refilling date.

[[#beginOfPage|Top]]

THIS PAGE IS OUTDATED !!! (CK, 15.11.08)

Mambo Bolometers at IRAM-30m

Description

The Mambo-1 and Mambo-2 bolometers have been developed at the Max-Planck-Institut fur Radiostronomie in Bonn by the group of Ernst Kreysa: MAMBO's 37 channel array has been successfully used by many observers since the end of 1998. Winter 2001/2002 was the first season of the new MAMBO-2 version with 117 pixels. The 37 channel MAMBO is used at the 30 m telescope as a backup system now. Both systems work at 1.2 mm wavelength and have a He-3 fridge to operate the bolometers at a temperature of 300 mK.

Top

Status

He-Refilling

When in use, Mambo1 or Mambo2 are currently refilled with He4 every 48 hours. This procedure takes about 4-5 hours. It can be used for heterodyne observations.

OnOff pixel

  • Mambo1: pixel 1 is the most sensitive.
  • Mambo2: pixel 20 is the most sensitive.

Dead/Noisy Pixels

Instabilities

  • Acceleration problem:
  • Gradient noise: about 6 % of scans are affected (stat. between 20.03.2007 and 30.03.2007)

Top

Observing modes

The bolometers have two basic modes of observations:

  • On-Off: flux measurement with a single pixel on a point-like source, using the wobbler switching.

  • Mapping: On-the-fly map using the wobbler switching. By default the on-the-fly scanning is along the azimuth direction together with the wobbler switching. It is now possible to rotate the wobbler with the scanning direction to get rotated map. The rotated angle is currently in the range [-60,60] degrees.

Top

Data Reduction

The data from the bolometer observations are recorded in IMBfits format. The data can be reduced using the Mopsic program (<zylka@iram.fr>) which is part of the GILDAS package.

Top

Technical Issues

Top

Contact Persons

Pool Manager: S. Leon (<leon@iram.es>)
Bolometer Expert: A. Sievers (<sievers@iram.es>)
Mambo/Abba expertise: G. Siringo (<gsiringo@mpifr-bonn.mpg.de>)
Mopsic development: R. Zylka (<zylka@iram.fr>)

Top

Top

MamboWebPage (last edited 2009-04-16 08:26:47 by localhost)