Mambo Bolometers at IRAM-30m

TableOfContents

Description

The Mambo-1 and Mambo-2 bolometers have been developed at the [http://www.mpifr-bonn.mpg.de/div/bolometer/ Max-Planck-Institut fur Radiostronomie] in Bonn by the group of Ernst Kreysa: MAMBO's 37 channel array has been successfully used by many observers since the end of 1998. Winter 2001/2002 was the first season of the new MAMBO-2 version with 117 pixels. The 37 channel MAMBO is used at the 30 m telescope as a backup system now. Both systems work at 1.2 mm wavelength and have a He-3 fridge to operate the bolometers at a temperature of 300 mK.

[#beginOfPage Top]

Status

Online

  • Mambo1 is currently not available.
  • Mambo2 is currently online

He-Refilling

Mambo1 or Mambo2 are currently refilled with He4 every 48 hours.

OnOff pixel

  • Mambo1: pixel 1 is the most sensitive.
  • Mambo2: pixel 20 is the most sensitive.

Dead/Noisy Pixels

Instabilities

  • Acceleration problem:
  • Gradient noise: about 6 % of scans are affected (stat. between 20.03.2007 and 30.03.2007)

[#beginOfPage Top]

Observing modes

The bolometers have two basic modes of observations:

  • On-Off: flux measurement with a single pixel on a point-like source, using the wobbler switching.

  • Mapping: On-the-fly map using the wobbler switching. By default the on-the-fly scanning is along the azimuth direction together with the wobbler switching. It is now possible to rotate the wobbler with the scanning direction to get rotated map. The rotated angle is currently in the range [-60,60] degrees.

[#beginOfPage Top]

Data Reduction

The data from the bolometer observations are recorded in IMBfits format. The data can be reduced using the Mopsic program (MailTo(zylka@iram.fr)) which is part of the GILDAS package.

[#beginOfPage Top]

Contact Persons

Pool Manager: S. Leon (MailTo(leon@iram.es)) BR Bolometer Expert: A. Sievers (MailTo(sievers@iram.es)) BR Mopsic development: R. Zylka (MailTo(zylka@iram.fr)) BR Mambo/Abba expertise: G. Siringo (MailTo(gsiringo@mpifr-bonn.mpg.de))