Differences between revisions 8 and 9
Revision 8 as of 2017-06-01 14:48:01
Size: 2396
Comment:
Revision 9 as of 2017-06-01 14:48:18
Size: 177
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
---- /!\ '''Edit conflict - other version:''' ----
= Detectors information =

[[Nika2Run5|Back to the NIKA2 Run 5 main page]] <<BR>>
[[Nika2Run6|Back to the NIKA2 Run 6 main page]]

----

REMEMBER: in the cryostat the polariser has horizontal wires. It means that the array 260GHz in transmission is sensitive to a polarisation vertical (E field vertical wrt the input window of the cryostat). The array 260GHz in reflection on the other hand is sensitive to a polarisation horizontal (E field horizontal wrt the input window of the cryostat).


----
=== 260 GHz band H (reflection) "array 1" ===
----

'''Array:''' 1mm_MSv1_02 - Al 18nm PTA

'''Pixels:''' 1140 pixels 2x2mm

'''Cold electronics:''' 8 amplifiers TTI Norte 2-3GHz (192.168.1.92, IN/OUT 5-12, E-F-G......L)

'''Warm electronics:''' "NIKA1" AMC rack, equipped with 8 cards, (synthesizer 2, 192.168.1.192, +10dBm), LO = 1.885GHz

'''Optics and spectrum:''' HDPE window and lenses with AR coating made with "pyramidal corrugations".

{{attachment:1mmHspectrum.jpg||height=415}}

<<BR>>

----
=== 150 GHz band ===
----
'''Array:''' 2mm_MSv0_02 (tested in run N1.5_030)

'''Pixels:''' 616 pixels, 2.75x2.75mm

'''Cold electronics:''' 4 Yebes L-band (1.2-1.8GHz) modified InP on channels 1,2 and 4. A classical L-band GaAs on channel 3. Controller amplis 192.168.1.93, IN/OUT 5-12, E-F-G......L

'''Warm electronics:''' "NIKA2" AMC rack, equipped with 4 cards, (synthesizer 8, 192.168.1.198, +7dBm), LO = 0.945GHz

'''Optics and spectrum:''' HDPE window and lenses with AR coating made with "pyramidal corrugations". New air-gap dichroic (flat). The spectrum is relatively flat between 145 and 165 GHz and has FWHM=130-170GHz. The central frequency is comprised between 150 and 155 GHz. WARNING: this spectrum measured in NIKA1.5 equipped with the same band-defining filter stack. However, the high-frequency filters and the lenses are not the same. We had no choice, NIKA2 was already gone..

{{attachment:2mmnewspec.jpg||height=415}}

[[NIKA2_commissioning_polar.pdf|NIKA2_polarization_commissioning_guidelines]]

---- /!\ '''Edit conflict - your version:''' ----
Line 54: Line 7:

---- /!\ '''End of edit conflict''' ----

NIKA2 polarization run preparation notes

nika2_polar.pdf

NIKA2_polarization_commissioning_guidelines

GoalsPrepStaffNika2Run11 (last edited 2017-06-10 12:31:58 by NikaBolometer)