NIKA2 Re-Commissioning (4th. attempt)
NIKA2 run 75, Cryo run 87
Oct. 13, 2025
14:00-17:00; Martino, Alessandro, Dave, Angel: a new sweep was performed. Previous initialization file: run87_old.ini. Bad/total KIDs counts (cryo window closed) after sweep (Ar1, Ar2, Ar3): 9/1000, 8/574, 4/1013. New file in force: run87_new.ini. Files run87_new_tp.ini and run87_new_pol.ini were also created. See nika2-a:~/nika_V3_IRAM.ini.
Oct. 14, 2025
We rename the ini files:
run87.ini (active file)
run87_old.ini (OLD active file, not used in August)
run87_newSweep_tp.ini
run87_newSweep_pol.ini
run87_oldSweep_tp.ini
run87_oldSweep_pol.ini
@15:00 LT we start, after preparing the whole "NIKA2 week environment architecture: 15/8/55 lost KIDs in Ar 1,2,3. Unstable sky and thick clouds coming from the N. We're entering in the peak of the tau forecast. It will be better later this evening. Meanwhile we try to focus. The old make-imbf script does not produce the imbfits files. Angel contacts Albrecht to solve the issue. The new make-imbf produces the file regularly.
On the very variable thick clouds, we notice a very different response of Ar1 and Ar3 to sky noise (variations), the latter having a bkg few times higher than the former (compare the y-axis scales). Is it real? Is there a flux calibration problem in the old DAFs? The a posteriori (19:00 LT) check does not reveal any calibration issue: Ar1 and Ar3 give similar fluxes for the targeted sources.
While we wait, some checks to some Antenna temperature control cables are being carried out by the telescope team. We start again 18:45 LT. The old make-imbf is now producing files correctly (thanks Albrecht!).
We work on the focus. Here follow our observations/notes. It is hard to get the focus value for all three arrays at once. The Ar2 flux criterion shows big jumps. The Ar2 FWHM and flux criteria do not agree. It almost seems like the flux is maximized not when the FWHM is minimized. Strange behavious, almost as if there were more than one "best" focus position. We enlarge the focus range of the 5 scans sequence. It was +/- 0.8 mm in steps of 0.4 mm. Now we changed it to +/- 1.0 mm, in steps of 0.5mm. The aim is to see if we can have a more complete sampling of the focus curve (for all criteria). The new script is called focusOTF-Z_2025.pako. We also try with a total excursion of +/-1.2 mm and steps of 0.6 mm. It seems that this latter solution is the best.
Is it possible that the difference in focus between Ar2 and Ar1 is changing? The first time it was ~0.3 mm. The second time it was ~0.6 mm. Now it is ~1.0mm??? At the same time, the focus difference between Ar1 and Ar3 seems stable at ~0.2 mm. It's early to be worried, but let's keep an eye on this! Nope, using the +/-1.2 mm excursion, we get back to 0.6mm difference between Ar2 and Ar1. Fiuuuu.
Focus sequences
Scan nr
Target
Ar2
Ar1
Ar3
Notes
20251013s161-165
2251+158
-0.3
+0.3
...
start at +0.2 mm; Big jumps in FWHM and flux during the focus sequence in Ar2
167-171
2251+158
~0.0
+0.9
1.1
start at +0.6 mm; Ar2 and Ar3 based on FWHM; El~40 deg; Ar2 FWHM and flux criteria do not agree
172-176
2251+158
-0.05
+1.0
~+1.2
start at +0.7; custom script with 0.5 mm step instead of 0.4 mm; is the difference between Ar2 and Ar1 become larger?
177-181
2251+158
+0.13
+0.75
+1.0
start at +0.7; custom script with 0.6 mm step instead of 0.4 mm; this is the best so far;
185-189
2251+158
+0.37
+1.21
...
start at +0.7; custom script with 0.6 mm step instead of 0.4 mm
191-195
2251+158
+0.34
+1.12
+1.42
start +1.0;
Beam maps (99 sub-scans) with the new SWEEP
Scan Nr
Target
Focus
Notes
20251013s183
2251+158
+0.15
Focus optimized For Ar2 @20:25 LT
2251+158
+0.34
Focus optimized For Ar2 @21:30 LT
Calibrators
Scan Nr
Target
Focus
Notes
Book-keeping of SWEEP changes
Scan Nr
SWEEP
20251013s124 to s182
OLD
20251013s183
NEW
20251013s184 to s196
OLD