'''January 14th 2014''': Andrea Catalano come to the 30m to turn on the NIKA cryostat and checking the cool down remotely controlled from Grenoble (Alessandro Monfardini and Martino Calvo). == January 14th 2014 ==

Andrea Catalano come to the 30m to turn on the NIKA cryostat and checking the cool down remotely controlled from Grenoble (Alessandro Monfardini and Martino Calvo).
Line 6: Line 8:
== STATUS == '''STATUS'''
Line 12: Line 14:
'''11h:''' Pressions stables. ZERO OF J1 IS -25mbar!!! '''11h:''' Pressions stables. '''ZERO OF J1 IS -25mbar!!!'''
Line 18: Line 20:
'''12h30m:''' Impedance 18mbar/min at 3bar. It is maybe less w.r.t. the last run cryo (not clear from the old files). WE
CONTINUE.
'''12h30m:''' Impedance 18mbar/min at 3bar. It is maybe less w.r.t. the last run cryo (not clear from the old files). '''WE
CONTINUE.'''
Line 21: Line 23:
'''13h:''' Leak test: OK, in the 1e-9 range.Pumped ev18 for 15 minutes. It was well empty in any case. REMEMBER NOT TO TOUCH ev18 ANYMORE. '''13h:''' Leak test: OK, in the 1e-9 range.Pumped ev18 for 15 minutes. It was well empty in any case. '''REMEMBER NOT TO TOUCH ev18 ANYMORE.'''
Line 28: Line 30:

'''15h30m:''' Lowering to 870mbar. Keep the same during the night.
Line 29: Line 33:
'''23h10m:''' T4K=160K. Tstill=125K. Lowering the flux at 630mbar for the night.

== January 15th 2014 ==

Cooling down still going on.


'''STATUS'''

'''07h00m:''' T4K=25K. Tstill=30K. Lowering the flux at 340mbar.

'''09h15m:''' Close ev5.

'''10h30m:''' Coax connected, mppsync connected, computers on (archeops 8-9-10) in the control room

'''11h00m:''' Condensation starts.

'''16h00m: 100mK !!!.'''

'''17h45m:''' Stop Compressor

''' 18h30m: Stop leak detecotr.

''' 18h30m: Nitrogen refill.

''' 18h30m: HWP modulator connected.

Back to the NIKA run 7

January 14th 2014

Andrea Catalano come to the 30m to turn on the NIKA cryostat and checking the cool down remotely controlled from Grenoble (Alessandro Monfardini and Martino Calvo).

STATUS

9h30: Reboot of the PC NIKA and change the VNC forwarding on the router.

10h: Pumped the trap (J5=46mbar). Pumped the dilution circuit (until Jpi=3e-2mbar).

11h: Pressions stables. ZERO OF J1 IS -25mbar!!!

12h: Connected the leak detector. Residual pressure in the cryostat 6.6mbar.

12h15m: Optical alignment of the cryostat started.

12h30m: Impedance 18mbar/min at 3bar. It is maybe less w.r.t. the last run cryo (not clear from the old files). WE CONTINUE.

13h: Leak test: OK, in the 1e-9 range.Pumped ev18 for 15 minutes. It was well empty in any case. REMEMBER NOT TO TOUCH ev18 ANYMORE.

13h: Optical alignment OK.

14h: GREEN LIGHT for switching on the Pulse Tube. Mixture circulated for two hours at 3bar.

14h30m: Pulse Tube on with 900mbar.

15h30m: Lowering to 870mbar. Keep the same during the night.

23h10m: T4K=160K. Tstill=125K. Lowering the flux at 630mbar for the night.

January 15th 2014

Cooling down still going on.

STATUS

07h00m: T4K=25K. Tstill=30K. Lowering the flux at 340mbar.

09h15m: Close ev5.

10h30m: Coax connected, mppsync connected, computers on (archeops 8-9-10) in the control room

11h00m: Condensation starts.

16h00m: 100mK !!!.

17h45m: Stop Compressor

18h30m: Stop leak detecotr.

18h30m: Nitrogen refill.

18h30m: HWP modulator connected.