Bolometer's Observation:

The most important commands of the old system have been adapted to the NCS. Here is a typical starting sequence for the bolometer.

Setup the Bolometer

Pako> @wbolo

Sources Catalog

Pako> catalog source pool ! Setup the project source catalog BR Pako> catalog source ihet ! Setup the pointing/calibration source catalog

<!> Pointing sources: J1419+240 not 1419+240

Focus, pointing, Skydip

Pako> focus 1.1 Pako> start ! Start the focus (!) Do a focus when atmospheric conditions are changing, typically after sunset/sunrise

Pako> p40 !Short length pointing for weak sources+start Pako> p60 !Long length pointing for strong sources+start (!) Before each OnOff or map if they are larger than 30 mn.

Pako> bt !Skydip at the current azimuth+start (!) Every 2 hours in stable atmospheric condition.

<!> Before an OnOff, be sure you are pointing at the right pixel (20).