Differences between revisions 12 and 15 (spanning 3 versions)
Revision 12 as of 2005-12-06 05:44:59
Size: 1516
Editor: visitor15
Comment:
Revision 15 as of 2005-12-06 06:03:09
Size: 1840
Editor: visitor15
Comment:
Deletions are marked like this. Additions are marked like this.
Line 18: Line 18:
Pako> '''focus 1.1''' Pako> '''focus 1.1''' [[BR]]
Line 20: Line 20:
Pako> '''set focus _sfcz_''' !''Correct the focus with _sfcz_. Correction from MOPSIC (@f or @fsn for weak sources)'' Pako> '''set focus sfcz''' !''Correct the focus with sfcz. Correction from MOPSIC (@f or @fsn for weak sources)''  [[BR]]
(!) Do a focus when atmospheric conditions are changing, typically after sunset/sunrise
Line 22: Line 23:
(!) Do a focus when atmospheric conditions are changing, typically after sunset/sunrise Pako> '''p40''' !''Short pointing for weak sources+start'' [[BR]]
Pako> '''p60''' !''Long pointing for strong sources+start'' [[BR]]
Pako> '''set pointing azcor elcor''' !''Correct the pointing with azcor and elcor. Correction from MOPSIC (@p or @psn for weak source)''
Line 24: Line 27:
Pako> '''p40''' !''Short length pointing for weak sources+start'' [[BR]]
Pako> '''p60''' !''Long length pointing for strong sources+start'' [[BR]]
Pako> '''set pointing _azcor_ _elcor_''' !''Correct the pointing with _azcor_ and _elcor_. Correction from MOPSIC (@p or @psn for weak source)''

(!) Before each Onoff or map if they are larger than 30 mn.
(!) Before each Onoff or map if they are longer than 30 mn.
Line 40: Line 39:
Calibration on a [primary|secondary] calibrator
Line 41: Line 41:
Pako> @wbolo
Pako> catalog ihet Calibrator_Name
Pako> p60
Pako> SET POINTING
Pako> '''@wbolo''' [[BR]]
Pako> '''catalog ihet Calibrator_Name ''' [[BR]]
Pako> '''p60''' [[BR]]
Pako> '''set pointing _azcor_ _elcor_''' [[BR]]
Pako> '''@onf4''' ! Shor Onoff integration (4 Subscans of 10 s)


<!> You may do a short @onf4 after a normal pointing to monitor the pointing sources flux.



== Onoff and map ==
On-Off observations:
 

Bolometer's Observation:

The most important commands of the old system have been adapted to the NCS. Here is a typical starting sequence for the bolometer.

Setup the Bolometer

Pako> @wbolo ! Mambo2, central pixel 53, short onoff (@onf4)

Sources Catalog

Pako> catalog source pool ! Setup the project source catalog BR Pako> catalog source ihet ! Setup the pointing/calibration source catalog

<!> Pointing sources: J1419+240 not 1419+240

Focus, pointing, Skydip

Pako> focus 1.1 BR Pako> start ! Start the focus BR Pako> set focus sfcz !Correct the focus with sfcz. Correction from MOPSIC (@f or @fsn for weak sources) BR (!) Do a focus when atmospheric conditions are changing, typically after sunset/sunrise

Pako> p40 !Short pointing for weak sources+start BR Pako> p60 !Long pointing for strong sources+start BR Pako> set pointing azcor elcor !Correct the pointing with azcor and elcor. Correction from MOPSIC (@p or @psn for weak source)

(!) Before each Onoff or map if they are longer than 30 mn.

Pako> bt !Skydip at the current azimuth+start

(!) Every 2 hours in stable atmospheric condition.

<!> Before an Onoff, be sure you are pointing with the right pixel (20).

Calibration

Calibration on a [primary|secondary] calibrator

Pako> @wbolo BR Pako> catalog ihet Calibrator_Name BR Pako> p60 BR Pako> set pointing _azcor_ _elcor_ BR Pako> @onf4 ! Shor Onoff integration (4 Subscans of 10 s)

<!> You may do a short @onf4 after a normal pointing to monitor the pointing sources flux.

Onoff and map

On-Off observations:

CookbookPako (last edited 2009-11-05 18:49:41 by lt-gq)