Differences between revisions 17 and 19 (spanning 2 versions)
Revision 17 as of 2016-03-02 18:25:47
Size: 1500
Editor: PabloGarcia
Comment:
Revision 19 as of 2016-03-02 18:26:46
Size: 1492
Editor: PabloGarcia
Comment:
Deletions are marked like this. Additions are marked like this.
Line 18: Line 18:
#where: where:
Line 20: Line 20:
# * ''' camera > ''' IRAM 30m continuum camera. Options are GISMO, NIKA1mm, NIKA2mm.
# * ''' rms > ''' Any value above the confussion limit.
# * ''' pwv > ''' Precipitable water vapor. Possible values 2, 4, and 7 mm.
# * ''' elevation > ''' Values from 20 to 83 degrees.
# * ''' Xsize Ysize > ''' Mapping area. Xsize and Ysize must be equal (point sources) or larger than the Field of View.
# * ''' filtering > ''' Data filtering scheme. Values from 1 to 4.
# * ''' overheads > ''' Telescope/observing overheads (calibration, pointing, focus). Values from 1.6 to 2.6.
 * ''' camera > ''' IRAM 30m continuum camera. Options are GISMO, NIKA1mm, NIKA2mm.
 * ''' rms > ''' Any value above the confussion limit.
 * ''' pwv > ''' Precipitable water vapor. Possible values 2, 4, and 7 mm.
 * ''' elevation > ''' Values from 20 to 83 degrees.
 * ''' Xsize Ysize > ''' Mapping area. Xsize and Ysize must be equal (point sources) or larger than the Field of View.
 * ''' filtering > ''' Data filtering scheme. Values from 1 to 4.
 * ''' overheads > ''' Telescope/observing overheads (calibration, pointing, focus). Values from 1.6 to 2.6.

Guidelines to estimate observing times with NIKA2

Guidelines to estimate observing times (Billot et al. 2014).

Python Script to estimate observing times.

To use the script, open a terminal in the same folder and type:

   python time-estimator-IRAM30m-nika-gismo.py --camera "GISMO" --rms 0.5 --pwv 2 --elevation 30 --Xsize 4 --Ysize 6 --filtering 1.2 --overheads 2.0

where:

  • camera > IRAM 30m continuum camera. Options are GISMO, NIKA1mm, NIKA2mm.

  • rms > Any value above the confussion limit.

  • pwv > Precipitable water vapor. Possible values 2, 4, and 7 mm.

  • elevation > Values from 20 to 83 degrees.

  • Xsize Ysize > Mapping area. Xsize and Ysize must be equal (point sources) or larger than the Field of View.

  • filtering > Data filtering scheme. Values from 1 to 4.

  • overheads > Telescope/observing overheads (calibration, pointing, focus). Values from 1.6 to 2.6.


Author: Pablo García (IRAM 30m Continuum Pool Manager)

email: pgarcia@iram.es

Created: 2014.Feb.10

Last update: 2016.Mar.02

Go to the GISMO |NIKA page.