= Pool Observations = From our experience, the chances of success of a program are higher if it is scheduled in a pool than in the traditional way of dedicated observing blocks. This is due to the flexibility of pooled observations concerning demand on weather quality and equipment availability. It is therefore advantageous for any project to participate in these pooled observing sessions. This means that the volunteer observers appointed in a given shift will receive from the pool managers a compendium of the observing projects to be tackled, depending on weather conditions, science targets visibility, project priorities and progress levels, etc. Participation in the pools is of additional interest for low-rated proposals that may otherwise not be scheduled. Astronomers with little or no experience are welcome as visitor observers at the IRAM 30m radio telescope. <> '''Go to the [[http://www.iram.es/IRAMES/mainWiki/Continuum/NIKA2/Main| NIKA2]] main page.''' ---- == Pool Logistics == Pool observations are carried from a dedicated pool account (ask the AoD for the login information of the NIKA2 account in force). Each project has a folder within the home directory of the pool account with instructions on how to proceed. Read carefully the README file before starting. For example, see the file [[attachment:README_001-17_v2.txt| ~/001-17/README_001-17.txt ]]. === Choose a project === First log into the [[https://pools.iram.es | IRAM 30m pools webpage]] (the PIs of a scheduled project can also access the database by using the login information of their project) and click on the NIKA2 tab. {{attachment:pools_database_w2022_1.png | NIKA2 projects | width=850 }} Projects have different priorities from 5 (highest priority) to 1 (lowest priority). Green color indicates that the project is '''scheduled''', orange that the project is '''on hold''', and red that the project is '''finished'''. Only green projects should be observed. To check the visibility of these projects go to the visibility tab: {{attachment:pools_database_w2022_2.png | Science Visibility plot | width=850}} The red vertical line corresponds to the current time (UT). In case none of the priority 5 projects have weather requirements (see the README files) compatible with the current conditions, go for priority 4 projects and so on, or according to the instructions given by the AoD. Finally, the IRAM 30m pools webpage can show you in real time a summary of the scans obtained per project by simply clicking on the project name and then on the "Logsheets" tab. The table obtained (see an example below) is an extract of the records automatically stored in the [[https://tapas.iram.es/tapas/| TAPAS]] server after each scan, together with the comments provided by the observer. {{attachment:pools_database_w2022_3.png | Science Visibility plot | width=850}} Take some time to explore all the dimensions of this useful database. In case of doubts, ask the AoD. == Visibility of flux standards == Among the calibration scans to be carried out over selected NIKA2 pool shifts (see [[https://publicwiki.iram.es/Continuum/ObservingSession | Observing session]] site), daily observations of flux standards are essential. Below are some plots of the planets and secondary flux calibrators suitable to be observed with NIKA2. The catalog of the latter ones (CalibNIKA.sou) is available in the pool account. All former secondary calibrators are listed here: http://www.iram.es/IRAMES/mainWiki/Continuum/Calibrators#preview. {{attachment:visibility_calibrators.png| Flux calibrators visibility plot | width=850}} === Project setup === The standard method to set the project is: {{{ PAKO> set project XXX-YY }}} However, for pooled observations, this is often done using a setup script (see for example [[attachment:setup_001-17_v1.txt | setup_001-17.pako ]]). For example, before starting to observe the project 001-17 you should type: {{{ PAKO> @ ~/001-17/setup_001-17.pako }}} It is IMPORTANT to set the project accordingly before each observation in order to identify the scans observed for each project, keep control on the time used to observe each project, and write the data files in the right directory. When you will be doing tests, or if you have to stop by wind, or whatever, just type '''set project test'''. That way, no project will loose time due to technical problems, or bad weather. For starting NIKA2 sessions of the pool and standard calibrations, use the pool account in force. === Catalog of sources === Before starting to observe a certain project it is necessary to load its catalog of sources. Usually, this is automatically done within the setup script. If for some reason you need to load the catalog manually, type: {{{ PAKO> SOURCE CATALOG 001-17.sou }}} This command will load the catalog [[attachment:001-17_v1.txt | 001-17.sou ]] with the position of NGC4449. To select this source, just type: {{{ PAKO> source NGC4449 }}} To select a source from the IRAM catalog of pointing sources, just type: {{{ PAKO> source pointing_source /cat * (or "iram-J2000.sou" for the given catalog) }}} ---- == Scripts preparation == Pooled observations should be fairly straightforward to observe. Note that your project will '''NOT''' be observed in case you do not send your observing instructions to the NIKA2 Pool Manager before the begin of the pool. It is highly recommended to use the standard scripts provided by the IRAM staff: ||[[attachment:README_001-17_v2.txt|README_001-17.txt]]||[[attachment:setup_001-17_v1.txt|setup_001-17.pako]]||[[attachment:001-17_v1.txt|001-17.sou]]||[[attachment:observe_NGC4449_v1.txt|observe_NGC4449.pako]]|| '''Note that this script uses a non-optimal scan size. For the optimum scan size, see the recommendation below. ''' You can download these example scripts and adapt them to your project. If you have questions please contact the pool manager. === Recommended scan sizes for science projects === To optimize the correction of data instabilities, the length of NIKA2 sub-scans, i.e. the size of scans along the scan direction should be at least: NIKA2 FOV (6.5') + 2 * NIKA2 beam width (12" at 1mm, 18" at 2mm) + source size above the noise + 2s * scan speed The third term makes sure that KIDs instabilities are properly corrected by data reduction. The fourth term is added because known tracking deviations of the 30m telescope can hinder the quality of data records, up to 2s after the beginning of each sub-scan. Perpendicularly to the scan direction, there is no minimum size limit, but too long scans can expose to a risk of losing tuning in the Data Acquisition System over time. Note that the size computed in this way is the Delta(x) described in the exposure time calculator documentation and not the size of the final map. The latter is larger by one FOV size. ---- == Pointing Sources == It is possible to select pointing sources nearby to your science targets using [[https://publicwiki.iram.es/Continuum/ObservingSession | XEphem]] and the [[http://www.iram.es/IRAMES/mainWiki/Continuum/Calibrators | IRAM 30m Catalog for Continuum Cameras]]. ---- == Mapping modes == We offer the on-the-fly (OTF) observing mode for the NIKA2 camera where data are taken continuously while the telescope follows a zig-zag pattern. The mode can be commanded as follows: ## Lissajous patterns are very efficient for point source observations as the target stays on-array during the scans (amplitude ~1 arcmin). We have noticed however that the '''strong telescope ## accelerations generated by the Lissajous scanning pattern produce some systematic noise at medium-to-large spatial scales (>20") in the reconstructed maps'''. While we are investigating the ## possibility to mitigate this extra noise (hardware and/or software), we currently consider the '''Lissajous observing mode not suitable for mapping extended emission'''. Instead the ## traditional zig-zag scanning pattern should be used for mapping extended emission or covering large areas. ## === Lissajous mode === ## Lissajous maps are square shaped and the coordinate system is always horizontal. Therefore, the only parameter needed is the amplitude of the Lissajous pattern. ## {{{ ## PAKO> @ cont_lissajous Size ## }}} ## For example, for a 1'x1' Lissajous map, type: ## {{{ ## PAKO> @ cont_lissajous 1 ## }}} ## {{attachment:lissajous.png | cont_lissajous 1 | width=700}} ## === On-the-fly mode === {{{ PAKO> @ nkotf xSize ySize posAngle tiltAngle otfStep otfSpeed System }}} where '''xSize''' and '''ySize''' are the size of the otf map in arcminutes, '''posAngle''' determines the angle of the scanning direction (anti-clockwise), '''tiltAngle''' determines the inclination of the scanning direction (anti-clockwise, useful to map filaments), '''otfStep''' is the spacing between OTF lines, '''otfSpeed''' is used to set the scanning speed (in arcseconds/sec), and '''System''' set the reference coordinate system (radec or azel). The '''nkotf''' command allows to generate plenty of different scanning patterns. In the following, some examples are shown. See also the last section of the wiki [[https://publicwiki.iram.es/Continuum/ObservingSession | Observing with NIKA2]]. {{{ PAKO> @ nkotf 5 5 0 0 20 40 azel }}} {{attachment:example1.png | nkotf 5 5 0 0 20 40 azel | width=700}} {{{ PAKO> @ nkotf 8 8 45 0 20 40 radec }}} {{attachment:example2.png | nkotf 8 8 45 0 20 40 radec | width=700}} {{{ PAKO> @ nkotf 2 12 30 +30 20 40 radec PAKO> @ nkotf 2 12 30 -30 20 40 radec }}} {{attachment:example3.png | cont_onthefly 2 12 30 +-30 20 40 radec | width=700}} Contact: Angel Bongiovanni, Ioannis Myserlis, Stergios Amarantidis ([[http://www.iram.es/IRAMES/mainWiki/Continuum/NIKA2/Main|NIKA2]] NIKA2 Pool Management) email: bongio@iram.es, imyserlis@iram.es, samarant@iram.es Created: 2013.OCT.25, H. Hermelo Updated: 2019.DEC.16, B. Ladjelate Last update: 2024.JAN.30, A. Bongiovanni